3.9 Article

Optical Biometry Changes Throughout Childhood and Adolescence in Patients Wearing Ortho-K Lenses

Journal

CLINICAL OPHTHALMOLOGY
Volume 17, Issue -, Pages 1919-1927

Publisher

DOVE MEDICAL PRESS LTD
DOI: 10.2147/OPTH.S413810

Keywords

orthokeratology; biometry; pediatrics; axial length; corneal thickness

Categories

Ask authors/readers for more resources

A retrospective longitudinal study was conducted at a tertiary eye care center in Ann Arbor, MI, USA to examine the changes in optical biometry parameters in Ortho-K patients. The results showed that Ortho-K did not significantly affect the overall trajectory of axial length progression, but it did lead to a reduction in corneal thickness.
Background: Orthokeratology has been shown to suppress progressive myopia in some children. We examine the changes in optical biometry parameters in orthokeratology (Ortho-K) patients, in a retrospective longitudinal study at a tertiary eye care center in Ann Arbor, MI, USA. Methods: Optical biometry measurements obtained with the Lenstar LS 900 (Haag-Streit USA Inc, EyeSuite software version i9.1.0.0) were aggregated from 170 patients who had undergone Ortho-K for myopia correction between 5 and 20 years of age. Pre intervention biometry measurements were compared with follow-up measurements done 6-18 months after initiation of Ortho-K. Linear mixed models were used to quantify associations in biometry changes with age of intervention allowing for correlation between measurements on two eyes of the same patient. Results: A total of 91 patients were included in the study. Axial length increased through the age of 15.7 & PLUSMN; 0.84 years for Ortho-K patients at our center. The growth curve in our Ortho-K population was comparable to previously published normal growth curves in Wuhan and Germany populations. Corneal thickness and keratometry decreased at a stable rate regardless of age of intervention (-7.9 & mu;m, 95% CI [-10.2, -5.7], p < 0.001). Conclusion: In our population, Ortho-K did not appear to affect the overall trajectory of axial length progression when compared to normal growth curves, despite showing a previously described reduction in corneal thickness. As Ortho-K has been shown to have varying effects that differ from individual to individual, it continues to be important to reassess its effects on new populations to better understand its ideal uses.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.9
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available