Keywords

electric vehicles (EVs); fractional-order control; frequency controller; manta ray foraging optimization; modern power grids

Ask authors/readers for more resources

The paper introduces an improved fractional-order frequency controller that optimizes the use of renewable energy sources and electric vehicle batteries in electrical power grids. The controller has superior performance characteristics, including faster response time, minimized overshoot/undershoot peaks, ability to mitigate high- and low-frequency disturbances, and coordination of electric vehicle participation in frequency regulation. The controller parameters are determined using the manta ray foraging optimization (MRFO) algorithm. Performance comparisons with existing PID, FOPID, and PD/FOPID controllers demonstrate the improved response and disturbance mitigation of the proposed controller.
Recent developments in electrical power grids have witnessed high utilization levels of renewable energy sources (RESs) and increased trends that benefit the batteries of electric vehicles (EVs). However, modern electrical power grids cause increased concerns due to their continuously reduced inertia resulting from RES characteristics. Therefore, this paper proposes an improved fractional-order frequency controller with a design optimization methodology. The proposed controller is represented by two cascaded control loops using the one-plus-proportional derivative (1 + PD) in the outer loop and a fractional-order proportional integral derivative (FOPID) in the inner loop, which form the proposed improved 1 + PD/FOPID. The main superior performance characteristics of the proposed 1 + PD/FOPID fractional-order frequency controller over existing methods include a faster response time with minimized overshoot/undershoot peaks, an ability for mitigating both high- and low-frequency disturbances, and coordination of EV participation in regulating electrical power grid frequency. Moreover, simultaneous determination of the proposed fractional-order frequency controller parameters is proposed using the recent manta ray foraging optimization (MRFO) algorithm. Performance comparisons of the proposed 1 + PD/FOPID fractional-order frequency controller with existing PID, FOPID, and PD/FOPID controllers are presented in the paper. The results show an improved response, and the disturbance mitigation is also obtained using the proposed MRFO-based 1 + PD/FOPID control and design optimization methodology.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available