4.6 Article

Flexural and shear behavior of ultra-high performance concrete segmental joints

Journal

STRUCTURES
Volume 56, Issue -, Pages -

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.istruc.2023.104913

Keywords

Ultra -high performance concrete; Segmental joint; Precast segment; Flexure; Shear

Ask authors/readers for more resources

The purpose of this study is to determine the optimum shape of ultra-high performance concrete (UHPC) segmental joints under flexural conditions and to investigate the flexural and shear capacities of UHPC segments connected by optimum segmental joints. The results show that the most effective joint shape is the 45 degrees key joint. The experimental results indicate that by inducing the prestressing forces, both flexural and shear performance predominantly increase.
The purpose of this study is to determine the optimum shape of ultra-high performance concrete (UHPC) segmental joints under flexural conditions and to investigate the flexural and shear capacities of UHPC segments connected by optimum segmental joints. A series of nonlinear finite element (FE) analyses is first performed to define the optimal shape and dimensions of the joint. The FE analysis results show that the most effective joint shape is the 45 degrees key joint, as it does not induce an overly high stress concentration at the joint. Therefore, fourteen UHPC segments connected with optimal joint configurations are prepared and tested under bending and shear loads. Several parameters, such as prestressing force, joint depth, the number of shear keys, and the presence of dowels, that affect the flexural and shear capacities of the UHPC segment are experimentally examined. The experimental results indicate that by inducing the prestressing forces, both flexural and shear performance predominantly increase, and higher ductile behavior in the UHPC segments can be achieved. Moreover, the presence of dowel bars and double shear keys can significantly retard crack opening at the joints under flexure and shear loading, respectively. This is because both dowel bars and key joints can facilitate the transfer of higher stresses across the joint. Additionally, the joint depth contributes positively to the stiffness and loading capacity of the UHPC segmental joints.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available