4.6 Article

Image Quality and Quantitative PET Parameters of Low-Dose [18F]FDG PET in a Long Axial Field-of-View PET/CT Scanner

Related references

Note: Only part of the references are listed.
Article Radiology, Nuclear Medicine & Medical Imaging

Application of the long axial field-of-view PET/CT with low-dose [18F]FDG in melanoma

Christos Sachpekidis et al.

Summary: The study aims to determine an appropriate acquisition time range for the new long axial field of view Biograph Vision Quadra PET/CT scanner in melanoma patients. The results show that low-dose LAFOV PET/CT imaging is feasible and can provide comparable diagnostic data to standard lengths of acquisition in a shorter scanning time, which is significant for the diagnostic work-up of melanoma patients.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2023)

Review Radiology, Nuclear Medicine & Medical Imaging

PET/CT in Non-Hodgkin Lymphoma: An Update

Lucia Zanoni et al.

Summary: Non-Hodgkin lymphomas encompass a diverse group of lymphoproliferative disorders with varying clinical courses. 18F-FDG-PET/CT is the current gold standard diagnostic imaging for staging, restaging, and treatment evaluation in lymphomas with high glucose avidity. PET-based response criteria are now uniformly applied in FDG-avid lymphomas, and this article provides updates on the management of diffuse large B-cell lymphoma, follicular lymphoma, and other histotypes, as well as the use of PET-derived factors for patient stratification and prognostication, and emerging radiomics research. Published in Semin Nucl Med 53:320-351 (c) 2022 by Elsevier Inc.

SEMINARS IN NUCLEAR MEDICINE (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

Impact of the new ultra-high sensitivity mode in a long axial field-of-view PET/CT

Clemens Mingels et al.

Summary: This study aimed to compare the impact of using the full acceptance angle (UHS) and the limited acceptance angle (high sensitivity mode, HS) on image reconstructions with the Biograph Vision Quadra LAFOV PET/CT. The results showed that using UHS significantly improved the signal-to-noise ratio and allowed for shorter acquisition times, which is advantageous for further reduction of whole-body PET/CT.

ANNALS OF NUCLEAR MEDICINE (2023)

Review Radiology, Nuclear Medicine & Medical Imaging

Long axial field of view (LAFOV) PET-CT: implementation in static and dynamic oncological studies

Antonia Dimitrakopoulou-Strauss et al.

Summary: Long axial field of view (LAFOV) PET-CT scanners have been recently developed and are already in clinical use in few centers worldwide, providing increased sensitivity for lesion detectability, reduced PET acquisition time and/or radiotracer dose, and improved attenuation correction approaches. However, challenges such as high purchase price, logistics issues, and the need for infrastructure in radiochemistry still need to be addressed. Overall, LAFOV PET-CT represents an important advancement in molecular imaging, with potential for dynamic imaging and improved oncological applications.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

Combined [68 Ga]Ga-PSMA-11 and low-dose 2-[18F]FDG PET/CT using a long-axial field of view scanner for patients referred for [177Lu]-PSMA-radioligand therapy

Ian Alberts et al.

Summary: Adding a low-dose 2-[F-18]FDG PET/CT as part of a same-day imaging protocol is feasible and can help detect lesions with low PSMA expression and play a role in therapy assessment.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

Characterization of the partial volume effect along the axial field-of-view of the Biograph Vision Quadra total-body PET/CT system for multiple isotopes

Julia G. Mannheim et al.

Summary: The study aimed to determine the contrast recovery coefficients (CRCs) and voxel noise levels for multiple isotopes throughout the 1.06 m axial field of view (FOV) of the Biograph Vision Quadra PET/CT system. Cylindrical phantoms with different sphere sizes and isotopes were used to evaluate the partial volume effect (PVE). The results showed distinct differences in PVE within the FOV, which can significantly affect the quantitative analysis of patient data. MRD322 resulted in slightly lower CRC values and significantly reduced voxel noise compared to MRD85.

EJNMMI PHYSICS (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

Long Versus Short Axial Field of View Immuno-PET/CT: Semiquantitative Evaluation for89Zr-Trastuzumab

Philipp Mohr et al.

JOURNAL OF NUCLEAR MEDICINE (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

Potential and Most Relevant Applications of Total Body PET/CT Imaging

Abass Alavi et al.

Summary: The introduction of total body PET/CT instruments has brought about a new era in medical imaging. These instruments with higher sensitivity allow for whole-body imaging, accurate assessment of disease extent, improved detection of cancer and chemotherapy complications, and evaluation of systemic diseases and musculoskeletal disorders.

CLINICAL NUCLEAR MEDICINE (2022)

Review Radiology, Nuclear Medicine & Medical Imaging

Hybrid total-body pet scanners-current status and future perspectives

Vanessa Nadig et al.

Summary: This study summarizes the current status and future developments of total-body PET/CT scanners, with three human TB PET/CT systems developed and increasing system sensitivity paving the way for new imaging methods.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Investigating ultra-low-dose total-body [18F]-FDG PET/CT in colorectal cancer: initial experience

Hui Tan et al.

Summary: In colorectal cancer patients, total-body PET/CT with an ultra-low dose of [18F]-FDG can maintain satisfactory image quality and lesion detectability.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Performance Characteristics of the Biograph Vision Quadra PET/CT System with a Long Axial Field of View Using the NEMA NU 2-2018 Standard

George A. Prenosil et al.

Summary: The performance of the Biograph Vision Quadra PET/CT system was evaluated in this study. The system showed improved sensitivity and count rates compared to the Biograph Vision 600 due to its larger field of view. The physical performance and image quality were assessed through various experiments and compared with existing PET scanners.

JOURNAL OF NUCLEAR MEDICINE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

EARL compliance measurements on the biograph vision Quadra PET/CT system with a long axial field of view

George A. Prenosil et al.

Summary: The study aimed to determine the reconstruction parameters for the Biograph Vision Quadra PET/CT system that would result in quantitative images compliant with the EARL criteria. The study also found that the high sensitivity of the Vision Quadra allows for short frames as short as 10 seconds to be feasible for quantitative imaging.

EJNMMI PHYSICS (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

EARL compliance and imaging optimisation on the Biograph Vision Quadra PET/CT using phantom and clinical data

Joyce van Sluis et al.

Summary: This study explores the compliance of the Siemens Biograph Vision Quadra PET/CT system with EARL specifications for F-18-FDG tumor imaging in LAFOV systems. Additional tests and clinical data were used to validate the effects of reducing scan duration on image accuracy and noise.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2022)

Review Oncology

Extending the clinical capabilities of short- and long-lived positron-emitting radionuclides through high sensitivity PET/CT

Joyce van Sluis et al.

Summary: This review discusses the benefits of using long axial field of view (LAFOV) PET in clinical applications. LAFOV PET systems have ultra-high sensitivity and offer various clinical applications, including dual tracer imaging and whole body dynamic PET imaging. It is expected that this generation of PET systems will significantly advance the field of nuclear medicine and molecular imaging.

CANCER IMAGING (2022)

Editorial Material Radiology, Nuclear Medicine & Medical Imaging

A Long Axial Field of View Enables PET/CT in Toddler Without Sedation

Michala Reichkendler et al.

JOURNAL OF NUCLEAR MEDICINE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Image quality assessment along the one metre axial field-of-view of the total-body Biograph Vision Quadra PET/CT system for 18F-FDG

Ivo Rausch et al.

Summary: This study aimed to assess the extent of useful aFOV of the Biograph Vision Quadra PET/CT system, with results showing stable image noise and contrast within the central 80 cm but increasing variability and noise beyond this range, particularly evident at short acquisition times.

EJNMMI PHYSICS (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Method to determine the statistical technical variability of SUV metrics

Giulia M. R. De Luca et al.

Summary: This study presents a method to determine the statistical technical variation of SUV in PET images. The method allows for the evaluation of the effect of SUV metric choice and lesion size on the technical variation and its relevance in clinical studies.

EJNMMI PHYSICS (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Optimizing acquisition times for total-body positron emission tomography/computed tomography with half-dose 18F-fluorodeoxyglucose in oncology patients

Yibo He et al.

Summary: This study aimed to determine the optimal acquisition time for total-body PET/CT oncological imaging and propose an acquisition time range. The study found that a 2-minute acquisition time provided acceptable performance in certain situations. Protocols with acquisition times of 5 minutes or longer could provide comparable lesion detectability as regular protocols.

EJNMMI PHYSICS (2022)

Article Oncology

PSMA and FDG-PET as predictive and prognostic biomarkers in patients given [177Lu]Lu-PSMA-617 versus cabazitaxel for metastatic castration-resistant prostate cancer (TheraP): a biomarker analysis from a randomised, open-label, 2 trial

James P. Buteau et al.

Summary: This study analyzed the predictive and prognostic value of gallium-68 [(68Ga)68Ga]Ga-PSMA-11 PET and 2-[18F]fluoro-2-deoxy-D-glucose PET imaging parameters in men with metastatic castration-resistant prostate cancer.

LANCET ONCOLOGY (2022)

Review Medicine, General & Internal

Immuno-PET: Design options and clinical proof-of-concept

Alexandre Lugat et al.

Summary: Radioimmunoconjugates have been widely used in nuclear medicine applications for over 30 years. Recent advances in cancer biology have led to the discovery of new molecular targets specific to certain patient subgroups, allowing for the development of specifically tailored therapeutic approaches. Immuno-positron emission tomography (immuno-PET) is a non-invasive imaging modality that utilizes monoclonal antibodies for in vivo characterization of tumor biomarkers, providing valuable information on tumor targeting. Immuno-PET shows great potential in various nuclear medicine applications, including staging/stratification, theranostic approaches, and predictive/prognostic biomarkers. Finding the right balance between isotope choice and immunologic structure is crucial for the development of radiopharmaceutical drugs for immuno-PET.

FRONTIERS IN MEDICINE (2022)

Review Radiology, Nuclear Medicine & Medical Imaging

The value of18F-FDG PET/CT for predicting or monitoring immunotherapy response in patients with metastatic melanoma: a systematic review and meta-analysis

Narjess Ayati et al.

Summary: The study investigated the ability of 18F-FDG PET/CT in assessing the response of metastatic melanoma patients to immunotherapy. Baseline SUVpeak, MTV, and TLG parameters were found to be promising predictors of treatment response. Modified response assessment criteria are potentially suitable for monitoring immunotherapy, and PET-detectable immune-related adverse events (irAEs) were associated with therapy response.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Total-body PET/CT using half-dose FDG and compared with conventional PET/CT using full-dose FDG in lung cancer

Hui Tan et al.

Summary: The study aimed to explore the effects of total-body PET/CT with half-dose F-18-FDG activity on image quality, and found that the image quality in the half-dose group was better than in the full-dose group. Through subjective and objective analyses, it was discovered that the image quality scores were higher in the half-dose group, and the liver signal-to-noise ratio was significantly higher as well.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT

Ian Alberts et al.

Summary: The study compared the performance of new LAFOV and standard SAFOV PET/CT systems using an intra-patient comparison. Results showed that the LAFOV system could achieve equivalent image quality and lesion quantification in a very short time, providing new possibilities for clinical applications.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2021)

Review Radiology, Nuclear Medicine & Medical Imaging

Pitfalls on PET/CT Due to Artifacts and Instrumentation

Yu-Jung Tsai et al.

Summary: PET/CT has become a preferred imaging modality in clinical practice, but pitfalls and image artifacts have been reported. Approaches to address these limitations and challenges for clinical applications are discussed in the literature.

SEMINARS IN NUCLEAR MEDICINE (2021)

Article Chemistry, Inorganic & Nuclear

Measurement of the branching ratio related to the internal pair production of Y-90

Pavel Dryak et al.

APPLIED RADIATION AND ISOTOPES (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Total Body PET: Why, How, What for?

Suleman Surti et al.

IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care

Simon R. Cherry et al.

JOURNAL OF NUCLEAR MEDICINE (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Reduction of 18F-FDG Dose in Clinical PET/MR Imaging by Using Silicon Photomultiplier Detectors

Tetsuro Sekine et al.

RADIOLOGY (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Technical note: how to determine the FDG activity for tumour PET imaging that satisfies European guidelines

Danille Koopman et al.

EJNMMI PHYSICS (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0

Ronald Boellaard et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2015)

Article Multidisciplinary Sciences

Quantitative and Qualitative Assessment of Yttrium-90 PET/CT Imaging

Ali Asgar Attarwala et al.

PLOS ONE (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Noise Considerations for PET Quantification Using Maximum and Peak Standardized Uptake Value

Martin A. Lodge et al.

JOURNAL OF NUCLEAR MEDICINE (2012)

Article Computer Science, Interdisciplinary Applications

Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction

Adam M. Alessio et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2010)