4.7 Article

Development of Magnetic Lateral Flow and Direct Competitive Immunoassays for Sensitive and Specific Detection of Halosulfuron-Methyl Using a Novel Hapten and Monoclonal Antibody

Journal

FOODS
Volume 12, Issue 14, Pages -

Publisher

MDPI
DOI: 10.3390/foods12142764

Keywords

halosulfuron-methyl; monoclonal antibody; magnetic lateral flow immunoassay

Ask authors/readers for more resources

A direct competitive ELISA and a magnetic lateral flow immunoassay (MLFIA) were developed to detect residues of Halosulfuron-methyl (HM) in tomato and maize matrices and paddy water, respectively. These methods showed high sensitivity and accuracy in the rapid detection of HM residues.
Halosulfuron-methyl (HM) is widely used for the removal of noxious weeds in corn, sugarcane, wheat, rice, and tomato fields. Despite its high efficiency and low toxicity, drift to nontarget crops and leaching of its metabolites to groundwater pose potential risks. Considering the instability of HM, the pyrazole sulfonamide of HM was used to generate a hapten and antigen to raise a high-quality monoclonal antibody (Mab, designated 1A91H11) against HM. A direct competitive immunoassay (dcELISA) using Mab 1A91H11 achieved a half-maximal inhibitory concentration (IC50) of 1.5 x 10(-3) mg/kg and a linear range of 0.7 x 10(-3) mg/kg-10.7 x 10(-3) mg/kg, which was 10 times more sensitive than a comparable indirect competitive ELISA (icELISA) and more simple to operate. A spiking recovery experiment performed in tomato and maize matrices with 0.01, 0.05, and 0.1 mg/kg HM had average recoveries within 78.9-87.9% and 103.0-107.4% and coefficients of variation from 1.1-6.8% and 2.7-6.4% in tomato and maize, respectively. In addition, a magnetic lateral flow immunoassay (MLFIA) was developed for quantitative detection of low concentrations of HM in paddy water. Compared with dcELISA, the MLFIA exhibited 3.3- to 50-fold higher sensitivity (IC50 0.21 x 10(-3) mg/kg). The average recovery and RSD of the developed MLFIA ranged from 81.5 to 92.5% and 5.4 to 9.7%. The results of this study demonstrated that the developed dcELISA and MLFIA are suitable for rapid detection of HM residues in tomato and maize matrices and paddy water, respectively, with acceptable accuracy and precision.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available