4.7 Article

Optimal design of energy-flexible distributed energy systems and the impacts of energy storage specifications under evolving time-of-use tariff in cooling-dominated regions

Journal

JOURNAL OF ENERGY STORAGE
Volume 72, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.est.2023.108462

Keywords

Energy flexibility; Distributed energy system; Optimal design; Time-of-use tariff; Energy storage

Categories

Ask authors/readers for more resources

This study investigates the optimal design of energy-flexible distributed energy systems in cooling-dominated regions and the impacts of energy storage parameters. The time-of-use tariff has significant impacts on system design, and increasing the peak-to-valley ratio can enhance the economic benefits. However, high unit prices of energy storages may make them economically unfavorable under all time-of-use tariffs.
To utilize the energy flexibility of demand side participants for achieving the global carbon-neutrality target, distributed energy systems (DESs) with active energy storages have attracted increasing attention. Existing studies mainly address the optimal configuration of DESs for enhanced energy flexibility. But the impacts of the energy storage specifications for DESs are rarely investigated, particularly under the evolving electricity markets towards carbon neutrality. This study, therefore, investigates the optimal design of energy-flexible DESs in cooling-dominated regions and the impacts of the economic and technical parameters of active energy storages under the evolving ToU tariff. A two-stage optimization method is developed for the optimal design of energyflexible DESs. A district in Hong Kong is chosen as a reference site to perform the design case studies and impact analysis. It is found that the ToU tariff has significant impacts on the optimal design of energy-flexible DESs. The increase of the peak-to-valley ratio generally can increase the life-cycle economic benefits of DES energyflexibility investment. The annualized life cycle cost of the optimized energy-flexible DES is decreased by up to $ 0.31 million when the peak-to-valley ratio increases from 2 to 10. A high unit price of energy storages (i.e., higher than 210 $/kWh for electric energy storages and 60 $/kWh for cold energy storages) will make them not economical to be adopted under all ToU tariffs. The maximum discharging rate of cold storages and the four specification parameters (i.e., the maximum charging rate, maximum discharging rate, charging/discharging efficiency, and lower limit of state of charge) of electric energy storages have considerable impacts on the energyflexible DES design, and therefore are recommended to be optimized in design.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available