4.8 Article

Interpretable Rule Mining for Real-Time ECG Anomaly Detection in IoT Edge Sensors

Journal

IEEE INTERNET OF THINGS JOURNAL
Volume 10, Issue 15, Pages 13095-13108

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JIOT.2023.3260722

Keywords

Anomaly detection; artificial neural network (ANN); electrocardiogram (ECG); explainability; heart rate variability (HRV); Internet of Things (IoT) edge sensors; rule-based algorithm

Ask authors/readers for more resources

This article proposes an explainable rule-mining strategy for prioritizing abnormal class detection in ECG data using an artificial neural network and rule-based system. The proposed model achieves high accuracy and sensitivity in detecting abnormal heartbeats through a comprehensive offline rule-mining process. It is suitable for healthcare applications due to its explainability, lower complexity, and real-time flexibility when deployed in IoT-enabled wearable edge sensors.
Electrocardiogram (ECG) analysis is widely used in the diagnosis of cardiovascular diseases. This article proposes an explainable rule-mining strategy for prioritizing abnormal class detection in ECG data. The proposed method utilizes a biased-trained artificial neural network (ANN) with input features derived from an ECG beat sequence and formulates a set of rules at each node of an on-demand tree-like search algorithm. The rule base at each node is derived from a linear combination of the most impactful features identified using gradient analysis in an ANN. The final derived model is an explainable rule-based system that detects abnormal heartbeats based on statistical and morphological features from ECG. The model achieves the target sensitivity, and accuracy with a low run time complexity through a comprehensive offline rule-mining process and is trained using the MIT-BIH Arrhythmia Database. The system achieves an accuracy of 93% with only nine nodes and a test sensitivity of 90% and 80%, respectively, for VEB and SVEB beat types, when tested on previously unseen ECG data from the INCART database. The model performance and complexity can be easily adjusted based on the real-time resource constraints of a wearable sensor. The model was deployed on an ARM Cortex M4-based embedded device and is shown to achieve a > 50% reduction in sensor power consumption when only abnormal beats are wirelessly transmitted. That is, RF transmission is gated using the model output and transmission is disabled when the subject's ECG is normal. The proposed technique is highly suited for healthcare applications because of its explainability, lower complexity, and real-time flexibility when deployed in the Internet of Things (IoT)-enabled wearable edge sensors.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available