4.6 Article

Mechanical stimuli such as shear stress and piezo1 stimulation generate red blood cell extracellular vesicles

Journal

FRONTIERS IN PHYSIOLOGY
Volume 14, Issue -, Pages -

Publisher

FRONTIERS MEDIA SA
DOI: 10.3389/fphys.2023.1246910

Keywords

red blood cells; piezo1; shear stress; extracellular vesicles; exosomes

Categories

Ask authors/readers for more resources

This study investigated the generation and isolation of high concentrations of red blood cell extracellular vesicles (RBC-EVs) using shear stress and piezo1 ion channel stimulation. The results showed that treating RBCs at 6% hematocrit with 10 μM yoda1 for 30 min and isolating RBC-EVs via ultracentrifugation produced the highest yield and purity, and had consistent preparations. Furthermore, co-isolated contaminants in impure samples induced vasodilation in mouse carotid artery, while piezo1 RBC-EVs did not.
Introduction: Generating physiologically relevant red blood cell extracellular vesicles (RBC-EVs) for mechanistic studies is challenging. Herein, we investigated how to generate and isolate high concentrations of RBC-EVs in vitro via shear stress and mechanosensitive piezo1 ion channel stimulation.Methods: RBC-EVs were generated by applying shear stress or the piezo1-agonist yoda1 to RBCs. We then investigated how piezo1 RBC-EV generation parameters (hematocrit, treatment time, treatment dose), isolation methods (membrane-based affinity, ultrafiltration, ultracentrifugation with and without size exclusion chromatography), and storage conditions impacted RBC-EV yield and purity. Lastly, we used pressure myography to determine how RBC-EVs isolated using different methods affected mouse carotid artery vasodilation.Results: Our results showed that treating RBCs at 6% hematocrit with 10 & mu;M yoda1 for 30 min and isolating RBC-EVs via ultracentrifugation minimized hemolysis, maximized yield and purity, and produced the most consistent RBC-EV preparations. Co-isolated contaminants in impure samples, but not piezo1 RBC-EVs, induced mouse carotid artery vasodilation.Conclusion: This work shows that RBC-EVs can be generated through piezo1 stimulation and may be generated in vivo under physiologic flow conditions. Our studies further emphasize the importance of characterizing EV generation and isolation parameters before using EVs for mechanistic analysis since RBC-EV purity can impact functional outcomes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available