4.6 Article

One-Dimensional W-NETR for Non-Invasive Single Channel Fetal ECG Extraction

Journal

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS
Volume 27, Issue 7, Pages 3198-3209

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JBHI.2023.3266645

Keywords

Fetal ECG; non-invasive ECG extraction; deep learning; W-NETR; transformers; self-attention mechanism; SSIM; PSNR

Ask authors/readers for more resources

Fetal cardiac monitoring is crucial for early detection of potential fetal cardiac abnormalities, enabling prompt preventative care and safe births.
Fetal cardiac monitoring is very helpful in the early detection of the potential risk of fetal cardiac abnormalities, which enables prompt preventative care and ensures safe births. As a result, it is crucial to regularly check on the embryonic heart. Methods of non-invasively fetal ECG extraction from maternal abdominal ECG signal are thoroughly discussed. Although fetal signals are generally obscured by maternal ECG signals and noise, extracting a clean fetal ECG is a significant difficulty. The majority of techniques for fetal ECG extraction include many extraction steps. We describe a unique method for splitting a single-channel maternal abdominal ECG into maternal and fetus ECG employing two parallel U-nets with transformer encoding, which we refer to as W-NEt TRansformers (W-NETR). Due to its enhanced capacity to simulate remote interactions and capture global context, the suggested pipeline utilizes the self-attention mechanism of the transformer. We tested the proposed pipeline on synthetic and real datasets and outperformed the current state-of-the-art deep learning models. The proposed model achieved the best results on both datasets for QRS detection precision, recall, and F1 scores. More specifically, it achieved F1 score of 99.88% and 98.9% on the real ADFECGDB and PCDB datasets, respectively. These encouraging results highlight the suggested W-NETR's effectiveness in precisely extracting the fetal ECG, which was achieved with high SSIM and PSNR values in the results. This provides the bed set for long-term maternal and fetal monitoring via portable devices as the proposed system performs real-time execution.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available