4.6 Article

Application of a Fluorescence-Based Instrument Prototype for Chlorophyll Measurements and Its Utility in an Herbicide Algal Ecotoxicity Assay

Journal

WATER
Volume 15, Issue 10, Pages -

Publisher

MDPI
DOI: 10.3390/w15101866

Keywords

aquafluosense; fluorescence; algae groups; in situ quantification; modular device; ecotoxicology; chlorophyll; isoxaflutole

Ask authors/readers for more resources

Project Aquafluosense aimed to develop prototypes for a modular fluorescence-based instrumental setup for in situ measurement of major water quality parameters. A fluorometer was developed for algal density estimation based on the fluorescent excitation of chlorophyll. The experimental results showed strong and positive correlation with conventional methods and demonstrated the applicability of the developed fluorometer in algal toxicity screening.
Project Aquafluosense was designed to develop prototypes for a modular fluorescencebased instrumental setup for in situ measurement of major water quality parameters. A fluorometer was developed for algal density estimation based on the fluorescent excitation of chlorophyll. The appropriate type of sample holder microplate was determined, along with the need for dark acclimation, prior to the measurements during the instrument's development. Model species of green (Raphidocelis subcapitata) and blue-green alga (Microcystis aeruginosa) were applied in forms of pure monocultures and their mixtures, and improved analytical limits of detection were achieved (3.70 x 10(3) cell/mL and 1.13 x 10(5) for R. subcapitata and M. aeruginosa, respectively). The fluorescence-based determination of algal density was validated by conventional methods, such as cell counting in a Burker chamber, optical density measurement, and chlorophyll extraction with ethanol. The signals obtained by the fluorometer correlated well with the conventional methods. Pearson r coefficients (applied where the correlation was linear) were >= 0.988 and Spearman rho coefficients (applied where the correlation was not linear) were >0.976, indicating a strong and positive correlation. The applicability of the developed fluorometer was demonstrated in a growth inhibition ecotoxicity assay on R. subcapitata using the herbicide active ingredient isoxaflutole. During the assay, light intensity (continuous, 104.9 +/- 14.9 mu E/m(2)/s), temperature (22 +/- 2 degrees C), pH of algal media (pH = 6-7 for Zehnder and Allen media, as well), and intensity of stirring (continuous, 100 rpm) were controlled. The results indicated that the FluoroMeter Module is applicable for screening algal toxicity: the observed ratio of fluorescence decrease determined by fluorescence induction provided significantly lower toxicity values (EC50: 0.015 +/- 0.001 mu g/mL) compared to values determined by the optical density (EC50: 0.034 +/- 0.004 mu g/mL) and chlorophyll a content (EC50: 0.033 +/- 0.000 mu g/mL).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available