4.5 Article

Mechanical properties of an elastically deformable cervical spine implant

Related references

Note: Only part of the references are listed.
Article Engineering, Biomedical

Mechanical characterization of a novel biomimetic artificial disc for the cervical spine

Celien A. M. Jacobs et al.

Summary: A novel biomimetic artificial intervertebral disc (bioAID) replacement implant has been developed and evaluated for its design safety based on biomechanical parameters. The results indicate that the implant can withstand shear-compression loads and mimic the behavior of natural disc under a diurnal loading pattern.

JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS (2023)

Article Biotechnology & Applied Microbiology

Biomechanical performance of the novel assembled uncovertebral joint fusion cage in single-level anterior cervical discectomy and fusion: A finite element analysis

Xiang Zhang et al.

Summary: An assembled uncoupled joint fusion device was designed to improve fusion rate and solve implantation difficulties. The device provided strong immobilization similar to the Zero-P device and achieved similar results in terms of facet contact force, intradiscal pressure, and screw-bone stress. Additionally, the assembled uncoupled joint fusion device effectively promoted early bone formation and fusion.

FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY (2023)

Review Orthopedics

A meta-analysis comparing the short- and mid- to long-term outcomes of artificial cervical disc replacement(ACDR) with anterior cervical discectomy and fusion (ACDF) for the treatment of cervical degenerative disc disease

Zihan Peng et al.

Summary: Artificial cervical disc replacement (ACDR) is comparable to anterior cervical discectomy and fusion (ACDF) in treating cervical degenerative disc disease (CDDD), but ACDR is superior in some success rates. ACDR can reduce the risk of dysphagia/dysphonia, adjacent segment disease (ASD), and reoperation.

INTERNATIONAL ORTHOPAEDICS (2022)

Article Orthopedics

Change in the postoperative intervertebral space height and its impact on clinical and radiological outcomes after ACDF surgery using a zero-profile device: a single-Centre retrospective study of 138 cases

Haimiti Abudouaini et al.

Summary: The effects of postoperative intervertebral height (IH) changes on clinical outcomes after ACDF surgery using a zero-profile device are not clear. Although no clear correlation was found between IH changes and clinical efficacy within a year of surgery, IH may affect various complications after ACDF. Maintaining postoperative IH changes at 2 to 4 mm may lead to satisfactory imaging parameters and relatively low complications after ACDF surgery using a zero-profile device.

BMC MUSCULOSKELETAL DISORDERS (2021)

Article Engineering, Biomedical

Design and material evaluation for a novel lumbar disc replacement implanted via unilateral transforaminal approach

Alba Gonzalez Alvarez et al.

JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS (2019)

Article Clinical Neurology

Anterior cervical interbody fusion with the Zero-P spacer: mid-term results of two-level fusion

Yuanyuan Chen et al.

EUROPEAN SPINE JOURNAL (2015)

Article Clinical Neurology

Zero-profile Anchored Spacer Reduces Rate of Dysphagia Compared With ACDF With Anterior Plating

Christoph P. Hofstetter et al.

JOURNAL OF SPINAL DISORDERS & TECHNIQUES (2015)

Article Engineering, Biomedical

Wear rate evaluation of a novel polycarbonate-urethane cushion form bearing for artificial hip joints

Jonathan J. Elsner et al.

ACTA BIOMATERIALIA (2010)

Article Clinical Neurology

Esophageal perforation from anterior cervical screw migration

Ramesh L. Sahjpaul

SURGICAL NEUROLOGY (2007)

Article Clinical Neurology

Intervertebral disc replacement maintains cervical spine kinetics

CM Puttlitz et al.

SPINE (2004)

Article Clinical Neurology

Intervertebral disc arthroplasty

PA Anderson et al.

SPINE (2004)