4.5 Article

Standardized 3D-printed trabecular titanium augment and cup for acetabular bone defects in revision hip arthroplasty: a mid-term follow-up study

Journal

Publisher

BMC
DOI: 10.1186/s13018-023-03986-0

Keywords

Standardized 3D-printed augment; Standardized 3D-printed cup; Trabecular titanium; Revision; Bone defect

Categories

Ask authors/readers for more resources

This study evaluated the feasibility and outcomes of using standardized 3D-printed trabecular titanium cups and augments to reconstruct acetabular defects. The results showed encouraging results in the mid-term follow-up, indicating that this method could be widely applied for repairing acetabular defects.
Background The aim of this study was to assess the feasibility and outcomes of standardized three-dimensional (3D)-printed trabecular titanium (TT) cups and augments to reconstruct most acetabular defects. Methods We included 58 patients with Paprosky type II and III acetabular bone defects who underwent revision hip arthroplasty between 2015 and 2018. Patients who were revised without 3D-printed augments, and cases who were lost to follow-up and died during follow-up were excluded. Radiographic and clinical outcomes were evaluated. A Kaplan-Meier survivorship curve was generated. The mean follow-up was 64.5 (range 49-84) months. Results In total, 48 (82.8%) acetabular revisions were performed using standardized 3D-printed TT cups and augments, and a retrospective review was conducted on 43 revisions. The average position of the vertical center of rotation and leg length discrepancy were significantly decreased from 42.4 +/- 9.1 mm and 38.4 +/- 10.7 mm to 22.8 +/- 3.4 mm and 4.1 +/- 3.0 mm, respectively. Non-progressive radiolucent lines were observed in 3 (7.5%) acetabular components with no indications for revision. The mean Harris hip score, Oxford hip score and EuroQol five-dimensional questionnaire score increased from 33.0 +/- 10.7, 11.4 +/- 3.4 and 0.29 +/- 0.09 to 80.3 +/- 8.8, 35.8 +/- 2.4 and 0.71 +/- 0.10, respectively. The revision-free survival rate of the acetabular component was 93.0% (40/43), with a rate of revision for aseptic loosening of 2.3% (1/43). Conclusion Standardized 3D-printed TT augments and cups could be used to reconstruct the majority of Paprosky type II and III acetabular defects in revision hip arthroplasty and demonstrated encouraging results at mid-term follow-up.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available