4.6 Article

Next generation covered stents made from nanocomposite materials: A complete assessment of uniformity, integrity and biomechanical properties

Journal

Publisher

ELSEVIER
DOI: 10.1016/j.nano.2015.07.002

Keywords

Nanotopography; Covered stent; Ultrasonic spray atomisation; Nanocomposite polymer; Interventional cardiology; Dip-coating; Stent manufacture

Funding

  1. Action Medical Research for Children
  2. EPSRC [EP/L024713/1] Funding Source: UKRI
  3. Engineering and Physical Sciences Research Council [EP/L024713/1] Funding Source: researchfish
  4. Action Medical Research [2100] Funding Source: researchfish

Ask authors/readers for more resources

Covered stents are stents wrapped with a thin polymeric membrane, and are typically used to treat vessel aneurysms and seal perforated arteries. Current covered stents suffer from restenosis due to limitations in material and fabrication methods which leaves metallic struts directly exposed to blood. We have developed a biocompatible and haemocompatible nanocomposite polymer, polyhedral oligomeric silsesquioxane poly(carbonate-urea) urethane (POSS-PCU). We devised a novel combination of ultrasonic spray atomisation system and dip-coating process to produce small calibre covered stents with metal struts fully embedded within the membrane, which also yields greater coating uniformity. Stent-polymer bonding was enhanced via silanisation and coating of reactive pre-polymer. Platelet studies supported the non-thrombogenicity of POSS-PCU. Biomechanical performances including diametrical compliance, bending strength, radial strength and recoil were evaluated and optimised. This proof-of-principle manufacturing technique could lead to the development of next-generation small calibre adult and paediatric covered stents. These stents are currently undergoing preclinical trial. From the Clinical Editor: The use of stents to treat vascular diseases is now the standard of care in the clinical setting. Nonetheless, a major problem of the current stents is the risk of restenosis and thrombosis. The authors developed a nanocomposite material using polyhedral oligomeric silsesquioxane and poly(carbonate-urea) urethane (POSS-PCU) and incorporated into metallic stents. Preliminary data have already shown promising results. It is envisaged that this would further lead to better stent technology in the future. (C) 2015 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available