4.5 Article

Early Termination versus Standard Regimen Duration of Dual Antiplatelet Therapy in Intracranial Aneurysm Patients Treated With Pipeline Embolization Device Flex With Shield Technology: Preliminary Experience of 3 US Centers

Related references

Note: Only part of the references are listed.
Article Clinical Neurology

First US Experience Using the Pipeline Flex Embolization Device with Shield Technology for Treatment of Intracranial Aneurysms

Justin M. Cappuzzo et al.

Summary: This study reports the initial results of using the PED-Shield for intracranial aneurysm treatment in a series of US patients. The device showed excellent performance and no major complications. A literature review revealed that most studies were conducted in Europe and South America, with only a few US case reports available.

WORLD NEUROSURGERY (2022)

Article Neuroimaging

Nuisance bleeding complications in patients with cerebral aneurysm treated with Pipeline embolization device

Elliot Pressman et al.

Summary: Nuisance bleeding is a common issue among PED-treated aneurysm patients who are on DAPT. Increasing age and aneurysmal occlusion at 6 months were the only predictive factors for nuisance bleeds. Clinicians are more likely to adjust antiplatelet regimens or stop DAPT early in response to nuisance bleeding.

JOURNAL OF NEUROINTERVENTIONAL SURGERY (2021)

Article Neuroimaging

Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results

Ricardo A. Hanel et al.

JOURNAL OF NEUROINTERVENTIONAL SURGERY (2020)

Article Clinical Neurology

Antiplatelet Therapy in Flow Diversion

Daniel A. Tonetti et al.

NEUROSURGERY (2020)

Editorial Material Clinical Neurology

Introduction: History and Development of Flow Diverter Technology and Evolution

Anna Luisa Kuhn et al.

NEUROSURGERY (2020)

Article Neuroimaging

Pipeline shield with single antiplatelet therapy in aneurysmal subarachnoid haemorrhage: multicentre experience

Nathan W. Manning et al.

JOURNAL OF NEUROINTERVENTIONAL SURGERY (2019)

Article Neuroimaging

Acute thrombus formation on phosphorilcholine surface modified flow diverters

Miklos Marosfoi et al.

JOURNAL OF NEUROINTERVENTIONAL SURGERY (2018)

Article Engineering, Biomedical

Thrombogenicity assessment of Pipeline Flex, Pipeline Shield, and FRED flow diverters in an in vitro human blood physiological flow loop model

Gaurav Girdhar et al.

JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A (2018)

Article Clinical Neurology

Aneurysm Study of Pipeline in an Observational Registry (ASPIRe)

David F. Kallmes et al.

INTERVENTIONAL NEUROLOGY (2016)

Article Cardiac & Cardiovascular Systems

In-vitro thrombogenicity assessment of flow diversion and aneurysm bridging devices

Gaurav Girdhar et al.

JOURNAL OF THROMBOSIS AND THROMBOLYSIS (2015)

Article Clinical Neurology

International Retrospective Study of the Pipeline Embolization Device: A Multicenter Aneurysm Treatment Study

D. F. Kallmes et al.

AMERICAN JOURNAL OF NEURORADIOLOGY (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial

Tibor Becske et al.

RADIOLOGY (2013)

Review Clinical Neurology

Flow Diversion for Intracranial Aneurysms A Review

Pietro I. D'Urso et al.

STROKE (2011)