4.7 Article

A centrifugal microfluidic platform for rapid detection of pathogens based on chitosan nucleic acid extraction and RAA-T7-CRISPR/Cas13a nucleic acid detection

Journal

SENSORS AND ACTUATORS B-CHEMICAL
Volume 393, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2023.134223

Keywords

Centrifugal microfluidic chip; Chitosan nucleic acid purification; CRISPR/Cas13a; Siphon valve; Sample-in-result-out bacterial detection

Ask authors/readers for more resources

This study developed a bacterial detection platform based on chitosan electrostatic adsorption for nucleic acid purification, RAA-T7-CRISPR/Cas13a system for nucleic acid quantification, and a centrifugal microfluidic platform for full-automatic operation. The platform showed the capability of automatically detecting Salmonella within 1 h, with a detection limit of 10 CFU/mL. The average recovery and standard deviation of the platform were 106.9% and 6.4%, respectively.
This study reported a bacterial detection platform using chitosan electrostatic adsorption for nucleic acid purification, RAA-T7-CRISPR/Cas13a system for nucleic acid quantification and centrifugal microfluidic platform for full-automatic operation. First, the nucleic acids in the lysed bacterial sample were captured by chitosan modified in the microfluidic PDMS channel through electrostatic adsorption, followed by washing with sodium acetate buffer solution. Then, these captured nucleic acid templates were eluted using Tris-HCl buffer solution through restoring the electrical neutrality of chitosan. Finally, the eluted nucleic acid templates were transferred into the RAA-T7-CRISPR/Cas13a system and isothermally amplified at 37 degrees C, followed by real-time detection of fluorescent products. A centrifugal microfluidic chip was elaborately designed with a chitosan modified channel, eight functional chambers and three siphon valves to achieve sequential capture, washing, elution, amplification and detection of nucleic acids. This platform has the capacity of automatically detecting Salmonella within 1 h. The detection limit of this platform was 10 CFU/mL in chicken supernatant under the use of optimal conditions. The average recovery and standard deviation of this platform are 106.9% and 6.4%, respectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available