4.6 Article

Dispersion Turning Attenuation Microfiber for Flowrate Sensing

Journal

SENSORS
Volume 23, Issue 16, Pages -

Publisher

MDPI
DOI: 10.3390/s23167279

Keywords

dispersion turning point; high attenuation fiber; anemometer; optical fiber sensor

Ask authors/readers for more resources

We have demonstrated a new optical fiber modal interferometer (MI) for airflow sensing, which is fabricated based on a piece of HAF. The interferometer shows a high sensitivity to changes in ambient temperature due to the absorption of HAF. A sample airflow sensor with high sensitivity and compact size has been made and exhibits a very high air-flow sensitivity of -2.69 nm/(m/s) at a flowrate of about 1.0 m/s.
We demonstrated a new optical fiber modal interferometer (MI) for airflow sensing; the novelty of the proposed structure is that an MI is fabricated based on a piece of HAF, which makes the sensitive MI itself also a hotwire. The interferometer is made by applying arc-discharge tapering and then flame tapering on a 10 mm length high attenuation fiber (HAF, 2 dB/cm) with both ends spliced to a normal single mode fiber. When the diameter of the fiber in the processing region is reduced to about 2 mu m, the near-infrared dispersion turning point (DTP) can be observed in the interferometer's transmission spectrum. Due to the absorption of the HAF, the interferometer will have a large temperature increase under the action of a pump laser. At the same time, the spectrum of the interferometer with a DTP is very sensitive to the change in ambient temperature. Since airflow will significantly affect the temperature around the fiber, this thermosensitive interferometer with an integrated heat source is suitable for airflow sensing. Such an airflow sensor sample with a 31.2 mm length was made and pumped by a 980 nm laser with power up to 200 mW. In the comparative experiment with an electrical anemometer, this sensor exhibits a very high air-flow sensitivity of -2.69 nm/(m/s) at a flowrate of about 1.0 m/s. The sensitivity can be further improved by enlarging the waist length, increasing the pump power, etc. The optical anemometer with an extremely high sensitivity and a compact size has the potential to measure a low flowrate in constrained microfluidic channels.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available