4.6 Article

Computation of medical radioisotopes cross section using level density models

Journal

RADIATION PHYSICS AND CHEMISTRY
Volume 216, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.radphyschem.2023.111390

Keywords

Radioisotopes production; Cross-section; Level density models

Ask authors/readers for more resources

In this study, cross sections of medical radioisotopes were calculated using level density models. The results were compared with experimental data and it was found that the GSM level density models generally yielded consistent conclusions.
The cross section is an important parameter in nuclear science it is obtained using different models in theoretical calculation way. Level density is one of the key input components for calculating the reaction cross sections in particular. In this study, the cross sections have been calculated using level density models on some medical radioisotopes. The calculation were performed using TALYS 1.95 computer program and the obtained data were compared with the available experimental data and the effect of level density models on 12C, 16O, 14N, 28Si, 63Cu, 90Zr,197Au,107Ag,186W radionuclides have been investigated. It is clear that GSM level density models generally give conclusions that are harmonious with existing experimental data.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available