4.6 Article

Investigation of the dosimetric properties of potassium hydrogen tartrate using EPR

Related references

Note: Only part of the references are listed.
Article Chemistry, Inorganic & Nuclear

ESR dosimetry with lithium, potassium, and sodium compounds

Amanda B. B. Rech et al.

Summary: This study presents the first investigation of materials for ESR dosimetry, emphasizing on radiological characteristics, dose sensitivity, and signal stability. Among the analyzed compounds, sodium citrate shows promising characteristics as a dosimeter material.

APPLIED RADIATION AND ISOTOPES (2022)

Article Instruments & Instrumentation

Cumulative dose experiments on Lithium formate monohydrate as an EPR-dosimeter for use in different radiation therapy scenarios

Ayoub Belahmar et al.

Summary: The dosimetric properties of lithium formate monohydrate (LFM) were studied, and its potential as a dosimeter in radiotherapy was investigated. It was found that LFM had a perfect linearity and slightly higher sensitivity to X-ray photons compared to proton and electron irradiations.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS (2022)

Article Chemistry, Physical

Radicals in ammonium tartrate at 295 K by X-radiation: Revised radical structures by EMR and DFT analyses

Einar Sagstuen et al.

Summary: This study investigates the disadvantages of using the amino acid ala for solid state radiation dosimetry and explores the potential of other compounds. The compounds ammonium tartrate and lithium formate were found to have higher sensitivity to radiation exposure. The study also reveals differences in the molecular structures of the dominant room temperature radical compared to previous theories.

RADIATION PHYSICS AND CHEMISTRY (2022)

Article Engineering, Biomedical

A practical EPR dosimetry system for routine use in radiotherapy: uncertainty analysis of lithium formate dosimeters at the therapeutic dose level

Sebastian Hoefel et al.

Summary: In EPR dosimetry, uncertainty analysis was conducted for doses ranging from 1 to 70 Gy using AL and LFM pellets. LFM pellets demonstrated lower dose uncertainties compared to AL pellets, making them more suitable for applications in radiotherapy.

PHYSICS IN MEDICINE AND BIOLOGY (2021)

Article Chemistry, Multidisciplinary

Preparation of New ESR Dosimetry System for High Dose Radiation Processing

Essam Mohamed Faheem et al.

EGYPTIAN JOURNAL OF CHEMISTRY (2020)

Article Physics, Atomic, Molecular & Chemical

Radiation Dosimetry Using Alanine and Electron Paramagnetic Resonance (EPR) Spectroscopy: A New Look at an Old Topic

Bernard A. Goodman et al.

APPLIED MAGNETIC RESONANCE (2017)

Article Chemistry, Physical

Alternative chitosan-based EPR dosimeter applicable for a relatively wide range of gamma radiation doses

Thananchai Piroonpan et al.

RADIATION PHYSICS AND CHEMISTRY (2017)

Article Nuclear Science & Technology

EPR dosimeter material properties of potassium tartrate hemihydrate

Norehan Mohd Nor et al.

RADIATION MEASUREMENTS (2016)

Article Physics, Atomic, Molecular & Chemical

Determination of New Radical Species in Ammonium Tartrate Dosimeters by CW- and Pulsed-EPR Techniques

Marina Brustolon et al.

APPLIED MAGNETIC RESONANCE (2015)

Article Chemistry, Physical

Alanine-EPR as a transfer standard dosimetry system for low energy X radiation

H. J. Khoury et al.

RADIATION PHYSICS AND CHEMISTRY (2015)

Article Chemistry, Inorganic & Nuclear

Taurine-EVA copolymer-paraffin rods dosimeters for EPR high-dose radiation dosimetry

Ahmed M. Maghraby et al.

NUKLEONIKA (2014)

Article Environmental Sciences

Investigation of radiation sensitivity of some tartrate compounds

M. O. Bal et al.

RADIATION PROTECTION DOSIMETRY (2014)

Article Nanoscience & Nanotechnology

Synthesis and Characterization of Gold/Alanine Nanocomposites with Potential Properties for Medical Application as Radiation Sensors

Eder Jose Guidelli et al.

ACS APPLIED MATERIALS & INTERFACES (2012)

Article Biology

Dosimetric and kinetic investigations of γ-irradiated sodium tartrate dihydrate

H. Tuner et al.

RADIATION AND ENVIRONMENTAL BIOPHYSICS (2012)

Article Instruments & Instrumentation

A sensitive EPR dosimetry system based on sulfamic acid

A. Maghraby

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS (2007)

Article Engineering, Biomedical

Uncertainties in alanine/ESR dosimetry at the Physikalisch-Technische Bundesanstalt

Mathias Anton

PHYSICS IN MEDICINE AND BIOLOGY (2006)

Article Chemistry, Inorganic & Nuclear

Development of a secondary standard for the absorbed dose to water based on the alanine EPR dosimetry system

M Anton

APPLIED RADIATION AND ISOTOPES (2005)

Article Chemistry, Inorganic & Nuclear

Development of ammonium tartrate as an ESR dosimeter material for clinical purposes

SK Olsson et al.

APPLIED RADIATION AND ISOTOPES (2000)

Article Instruments & Instrumentation

Assessment of an alanine EPR dosimetry technique with enhanced precision and accuracy

RB Hayes et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2000)