4.7 Article

The study of coal dust minimum explosion concentration of subbituminous coal

Journal

PROCESS SAFETY AND ENVIRONMENTAL PROTECTION
Volume 177, Issue -, Pages 1387-1392

Publisher

ELSEVIER
DOI: 10.1016/j.psep.2023.08.002

Keywords

Coal Dust Explosion; Minimum Explosion Concentration; Explosion Chamber; Ignitor Energy

Ask authors/readers for more resources

The coal dust explosion tests were conducted in a 20-L explosion chamber using subbituminous coal from Indonesia with coal dust sizes of 53-44 μm (average particle size of 48.5 μm). Different energies of ignitor (4.2 kJ, 6.3 kJ, and 8.4 kJ) were used to study the effect on the Minimum Explosion Concentration (MEC) of the coal dust. The results showed that the MEC for ignitor energies of 4.2 kJ, 6.3 kJ, and 8.4 kJ were 120 g/m3, 100 g/m3, and 70 g/m3, respectively. Compared to previous studies on bituminous coal, this study found a higher MEC in subbituminous coal.
The coal dust explosion tests have been conducted using an explosion chamber 20-L with coal dust sizes of 53-44 & mu;m (average particle size is 48.5 & mu;m) for subbituminous coal from Indonesia. The coal dust explosion has been tested with various energies of the ignitor, i.e., 4.2 kJ, 6.3 kJ, and 8.4 kJ, to obtain the effect of ignitor energy on the coal dust's Minimum Explosion Concentration (MEC). The results show that the MEC for the 4.2 kJ, 6.3 kJ, and 8.4 kJ ignitor energy are 120 g/m3, 100 g/m3, and 70 g/m3, respectively. The present study in subbitu-minous coal resulted in a relatively higher MEC compared to previous studies conducted in bituminous coal.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available