Analysis of biometric parameters of cataract eyes measured with optical biometer Lenstar LS900, IOL Master 700, and OPD-SCAN III

Related references

Note: Only part of the references are listed.
Article Ophthalmology

Characteristics and factors associated with the position of the haptic after ICL V4C implantation

Weina Tan et al.

Summary: The position of ICL haptic after ICL V4C implantation was assessed using UBM, and its characteristics, associated factors, and relationship with the clinical vault were analyzed. The results showed that the position of ICL haptic was associated with the clinical vault. Quantitative evaluation of ICL haptic position can help clinicians select the appropriate ICL size before surgery and understand the formation of the clinical vault after surgery.

JOURNAL OF CATARACT AND REFRACTIVE SURGERY (2023)

Article Ophthalmology

Visual and Refractive Outcomes of a Trifocal Toric Intraocular Lens Implanted in Eyes With High Corneal Astigmatism

Ramon Ruiz-Mesa et al.

Summary: This study analyzed the refractive and visual outcomes of cataract surgery and implantation of a trifocal toric intraocular lens (IOL) in eyes with high corneal astigmatism. The results showed that most eyes achieved good refractive and visual outcomes during a follow-up period of 1 to 5 years.

JOURNAL OF REFRACTIVE SURGERY (2023)

Article Oncology

Agreement of anterior segment measurements between LenStar LS 900 optical biometer and OPD Scan III wavefront aberrometer devices in eyes with cataract

Tong Bao et al.

Summary: This study compared the inter-device agreement of anterior eye segment measurements between LenStar LS 900 optical biometer and OPD Scan III wavefront aberrometer. The results showed excellent agreement between these two devices for measurements of white-to-white distance, angle Alpha, angle Kappa, and pupil size. Therefore, these measurements can be used interchangeably in clinical practice.

PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY (2023)

Article Medicine, General & Internal

Effect of pupil dilation on biometry measurements and intraocular lens power in eyes with high myopia

Wenqun Xi et al.

Summary: This study evaluated the effects of pupil dilation on ocular parameter measurements and IOL power calculation in highly myopic cataract patients. The results showed that pupil dilation significantly increased anterior chamber depth and white-to-white values, while decreasing lens thickness. Surgeons should consider the effect of pupil dilation on IOL power prediction.

FRONTIERS IN MEDICINE (2022)

Article Engineering, Biomedical

Agreement of anterior segment measurements between four diagnostic imaging devices in myopic patients

John Placide et al.

Summary: This study compares the inter-device agreement of various eye measurements and indicates that different instruments have interchangeable capabilities for measuring ACD, CCT, K1, K2, Delta K, and WTW, with each device having its own strengths in certain measurements.

EXPERT REVIEW OF MEDICAL DEVICES (2021)

Article Ophthalmology

Should Artificial Tears Be Used During the Preoperative Assessment of Toric IOLs Before Age-Related Cataract Surgery? The TORIDE Study

Elsa Rochet et al.

Summary: The use of artificial tears before cataract surgery can affect corneal astigmatism and toric IOL calculations, reducing refractive errors.

JOURNAL OF REFRACTIVE SURGERY (2021)

Article Ophthalmology

Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500

Ahmet Akman et al.

BRITISH JOURNAL OF OPHTHALMOLOGY (2016)

Article Ophthalmology

Comparison of 2 laser instruments for measuring axial length

Kenneth J. Hoffer et al.

JOURNAL OF CATARACT AND REFRACTIVE SURGERY (2010)

Article Ophthalmology

A new optical low coherence reflectometry device for ocular biometry in cataract patients

P. J. Buckhurst et al.

BRITISH JOURNAL OF OPHTHALMOLOGY (2009)

Article Ophthalmology

A new non-contact optical device for ocular biometry

J Santodomingo-Rubido et al.

BRITISH JOURNAL OF OPHTHALMOLOGY (2002)