4.4 Article

Increased beam energy as a pathway towards a highly selective and high-flux MR-ToF mass separator

Publisher

ELSEVIER
DOI: 10.1016/j.nima.2023.168545

Keywords

MR-ToF device; Short-lived radionuclides; MIRACLS; Electrostatic ion beam traps; Mass separation; Space charge

Ask authors/readers for more resources

Isobaric contamination is a common issue in radioactive ion beam (RIB) experiments. Multi-Reflection Time-of-Flight (MR-ToF) devices have been widely used for mass separation, but the presence of space-charge effects limits their application. This study uses ion-optical simulations to investigate different ion preparation schemes and MR-ToF operation, and suggests that advanced ion-beam preparation techniques can reduce processing time, but also increase space-charge effects.
Many experiments at radioactive ion beam (RIB) facilities suffer from isobaric contamination, i.e. unwanted ions of similar mass. During the last decade, Multi-Reflection Time-of-Flight (MR-ToF) devices have gained remarkable attention for mass separation of short-lived, low-intensity beams of radionuclides at RIB facilities throughout the world. They exceed mass resolving powers m/Delta m of 10(5) within a processing time of some (tens of) milliseconds. Due to space-charge effects, however, the mass separation remains an experimental challenge when many ions are simultaneously confined in the MR-ToF device. This limits the wider application of MR-ToF mass separators at RIB facilities. By performing ion-optical simulations including space-charge effects, we investigate different schemes of ion preparation in a Paul trap upstream of the MR-ToF device as well as MR-ToF operation and study their influence on mass separation and maximal ion flux. The validity of these simulations are benchmarked by time-of-flight and collision-induced fluorescence measurements with a 1.5 keV MR-ToF device. More advanced ion-beam preparation techniques such as the use of laser cooling, buffer-gas cooling at cryogenic temperatures or specific electric-field parameters for ion trapping and ejection from the Paul trap can significantly reduce the processing time needed to reach a given mass resolving power. However, the simulations of these methods also indicate that space-charge effects in the MR-ToF device become relevant at lower ion numbers compared to 'standard' ion preparation. Thus, the overall amount of mass separated ions per unit of time remains essentially the same. In contrast, the simulations suggest that increasing the kinetic energy of typically just a few kiloelectronvolts in present MR-ToF instruments to 30 keV results in a significant increase of the attainable maximal ion flux.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available