4.4 Article

Comparison of diffusion weighted imaging b0 with T2*-weighted gradient echo or susceptibility weighted imaging for intracranial hemorrhage detection after reperfusion therapy for ischemic stroke

Journal

NEURORADIOLOGY
Volume -, Issue -, Pages -

Publisher

SPRINGER
DOI: 10.1007/s00234-023-03180-3

Keywords

Ischemic stroke; Reperfusion; MRI; Intracranial hemorrhage

Ask authors/readers for more resources

This study compared the diagnostic accuracy of diffusion-weighted imaging (DWI) b0 with T2*-weighted gradient echo (GRE) or susceptibility-weighted imaging (SWI) for detection of hemorrhage in ischemic stroke patients after reperfusion therapy. The results showed that DWI b0 had lower sensitivity for detecting hemorrhage, especially for smaller and more subtle hemorrhages. Therefore, follow-up MRI protocols should include T2*GRE or SWI for detection of hemorrhage after reperfusion therapy.
PurposeDiffusion-weighted imaging (DWI) b0 may be able to substitute T2*-weighted gradient echo (GRE) or susceptibility-weighted imaging (SWI) in case of comparable detection of intracranial hemorrhage (ICH), thereby reducing MRI examination time. We evaluated the diagnostic accuracy of DWI b0 compared to T2*GRE or SWI for detection of ICH after reperfusion therapy for ischemic stroke.MethodsWe pooled 300 follow-up MRI scans acquired within 1 week after reperfusion therapy. Six neuroradiologists each rated DWI images (b0 and b1000; b0 as index test) of 100 patients and, after a minimum of 4 weeks, T2*GRE or SWI images (reference standard) paired with DWI images of the same patients. Readers assessed the presence of ICH (yes/no) and type of ICH according to the Heidelberg Bleeding Classification. We determined the sensitivity and specificity of DWI b0 for detection of any ICH, and the sensitivity for detection of hemorrhagic infarction (HI1 & HI2) and parenchymal hematoma (PH1 & PH2).ResultsWe analyzed 277 scans of ischemic stroke patients with complete image series and sufficient image quality (median age 65 years [interquartile range, 54-75], 158 [57%] men). For detection of any ICH on DWI b0, the sensitivity was 62% (95% CI: 50-76) and specificity 96% (95% CI: 93-99). The sensitivity of DWI b0 was 52% (95% CI: 28-68) for detection of hemorrhagic infarction and 84% (95% CI: 70-92) for parenchymal hematoma.ConclusionDWI b0 is inferior for detection of ICH compared to T2*GRE/SWI, especially for smaller and more subtle hemorrhages. Follow-up MRI protocols should include T2*GRE/SWI for detection of ICH after reperfusion therapy.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available