Use of scanners for colorimetric analysis of microfluidic paper-based analytical devices (μPADs): A practical guide

Journal

MICROCHEMICAL JOURNAL
Volume 191, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.microc.2023.108879

Keywords

Flatbed scanner; Sheet-fed scanner; Colorimetric analysis; contact image sensor (CIS) technology; Reflectance microfluidic paper-based analytical devices (mu PADs)

Ask authors/readers for more resources

This study evaluated the influence of scanner settings, data analysis methods, and physical characteristics of the micro-fluidic paper-based analytical devices (mu PADs) on colorimetric detection. The most sensitive calibration curve was achieved by selecting optimal scanning conditions and a suitable colorimetric system. A flatbed scanner showed greater variation in response under different scanning conditions, while a portable scanner provided consistent responses. Parameters such as gamma correction, scanning resolution, and pixel analysis did not markedly affect the calibration curve. Factors that influenced colorimetric detection included scanner settings, blank color, image acquisition mode, and mu PAD covering. Based on these findings, generic guidelines for optimal data acquisition and mu PAD manipulation have been formulated with respect to mu PAD calibration.
Office style scanners are often used by researchers for the colorimetric detection in the development of micro-fluidic paper-based analytical devices (mu PADs). However, little attention has been paid to nuances in calibration curve responses caused by varying settings of a single image-capturing device. Hence, in this study, the effect of parameters, such as the scanner operation conditions, the method of data analysis used (e.g., choice of colour space system, suitable channel), and the influence of the physical characteristics of the mu PAD (e.g., template colour, type of lamination pouches used) on the colorimetric detection were evaluated for the first time. Combinations of the scanning parameters were thoroughly examined and their impact on the quality of a mock calibration curve assessed. The most sensitive calibration curve was achieved only by the selection of the optimal scanning conditions combined with an appropriate choice of colorimetric system. A flatbed scanner, used in this study, showed greater variation of signal with varying scanning setup, whereas a portable scanner provided nearly identical responses under diverse scanning conditions. Gamma correction, scanning resolution, region of interest (ROI) surrounding colour (i.e., template colour), bit-depth, image file type, and the number of analysed pixels were found not to markedly affect the dynamics of the calibration curve when colour in the ROI is homogeneous. Parameters that had an effect on the colorimetric detection were the scanner settings, colour of the blank, image acquisition mode (colour vs greyscale), and mu PAD covering (e.g., lamination). Based on these findings, generic guidelines for optimal data acquisition and mu PAD manipulation with respect to mu PAD calibration have been formulated.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available