4.7 Article

Electromembrane extraction of anesthetic ketamine on-line coupled to capillary electrophoresis

Journal

MICROCHEMICAL JOURNAL
Volume 191, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.microc.2023.108886

Keywords

Capillary electrophoresis; Electromembrane extraction; Human urine; Ketamine; On-line coupling

Ask authors/readers for more resources

This article introduces a method for extracting the anesthetic ketamine using electromembrane extraction coupled with capillary electrophoresis. The extraction occurs in a flow-through extraction mini probe, consisting of a porous hollow fiber filled with nitrophenyloctyl ether as extraction liquid. The pH of the sample solution does not affect the extraction efficiency, and the calibration dependence is linear in both model samples and urine. The LOD values are around 1 µM.
The anesthetic ketamine is extracted from the sample solutions by electromembrane extraction on-line coupled with capillary electrophoresis (CE) at a short separation path. Ketamine is extracted from model acidic and alkaline aqueous solutions, or from untreated human urine as donor into an acidic acceptor solution, which acts also as background electrolyte for CE. Extraction occurs in a flow-through extraction mini probe with an internal volume of 1.1 mu L, consisting of a porous hollow fiber with pores filled with nitrophenyloctyl ether as extraction liquid. The probe is immersed in a 1.5 mL vial of analyte solution, the vial is vibrationally agitated during extraction, and ketamine is extracted at 150 V for 300 s. It was found that the pH of the sample solution does not affect the extraction efficiency, i.e., it does not depend on whether ketamine is in the protonated form or as a neutral molecule during extraction; the enrichment factor is 16-19, the recovery factor 1.5 %. The calibration dependence is linear in both model samples in the concentration range 2 to 50 mu M and in urine in the con-centration range 2.5 to 10 mu M with the same slope in both sample types. The LOD values are around 1 mu M. The extraction probe is reusable. However, between runs a purification process with the probe immersed in the background electrolyte is necessary to remove ketamine trapped in the membrane liquid.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available