4.7 Article

Low-field magnetic resonance image enhancement via stochastic image quality transfer

Journal

MEDICAL IMAGE ANALYSIS
Volume 87, Issue -, Pages 1-16

Publisher

ELSEVIER
DOI: 10.1016/j.media.2023.102807

Keywords

Low-field MRI; Deep neural networks; Image quality transfer; Stochastic simulator

Ask authors/readers for more resources

Low-field (<1T) MRI scanners are widely used in low- and middle-income countries and have some applications in higher income countries. However, the images produced by low-field MRIs usually have lower resolution and poorer contrast compared to high-field MRIs. In this study, we propose an Image Quality Transfer (IQT) method to enhance low-field structural MRI by estimating the image that would have been obtained from the same subject at high-field. Our approach uses a stochastic low-field image simulator and an anisotropic U-Net variant specifically designed for the IQT inverse problem. We evaluated the algorithm using simulation and real clinical low-field MRI data, and demonstrated the efficacy of IQT in improving contrast and resolution of low-field MR images.
Low-field (< 1T) magnetic resonance imaging (MRI) scanners remain in widespread use in low-and middle -income countries (LMICs) and are commonly used for some applications in higher income countries e.g. for small child patients with obesity, claustrophobia, implants, or tattoos. However, low-field MR images commonly have lower resolution and poorer contrast than images from high field (1.5T, 3T, and above). Here, we present Image Quality Transfer (IQT) to enhance low-field structural MRI by estimating from a low-field image the image we would have obtained from the same subject at high field. Our approach uses (i) a stochastic low-field image simulator as the forward model to capture uncertainty and variation in the contrast of low-field images corresponding to a particular high-field image, and (ii) an anisotropic U-Net variant specifically designed for the IQT inverse problem. We evaluate the proposed algorithm both in simulation and using multi-contrast (T1-weighted, T2-weighted, and fluid attenuated inversion recovery (FLAIR)) clinical low -field MRI data from an LMIC hospital. We show the efficacy of IQT in improving contrast and resolution of low-field MR images. We demonstrate that IQT-enhanced images have potential for enhancing visualisation of anatomical structures and pathological lesions of clinical relevance from the perspective of radiologists. IQT is proved to have capability of boosting the diagnostic value of low-field MRI, especially in low-resource settings.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available