4.7 Article

Enhanced transverse nuclear magnetization of an atomic co-magnetometer at the optimal oscillating magnetic field

Related references

Note: Only part of the references are listed.
Article Engineering, Multidisciplinary

The frequency shift of 129Xe and 131Xe nuclei in NMR sensors caused by weak temperature gradients

Hao Tian et al.

Summary: This study discusses the frequency shift phenomenon of 129Xe and 131Xe in NMR sensors caused by weak temperature gradients. A new model based on thermal diffusion and relative concentration is proposed to explain this phenomenon, and simulations are conducted using COMSOL software. The results show good agreement with experimental data, providing a valuable reference for analyzing the frequency shift of NMR sensors under weak temperature gradients.

MEASUREMENT (2023)

Article Automation & Control Systems

Parameter Modeling Analysis of a Cylindrical Ferrite Magnetic Shield to Reduce Magnetic Noise

Danyue Ma et al.

Summary: This article examines the importance of magnetic field shields for electronic equipment, ultrahigh-sensitivity sensors, and electrical instruments. It analyzes the calculation methods of longitudinal and transverse magnetic noise using loss separation. Experimental results confirm the feasibility of the model, and optimized parameters are obtained for reducing magnetic noise by analyzing the effect of structure parameters. The results show that longitudinal magnetic noise decreases with increasing aspect ratio, while transverse magnetic noise remains unchanged when the aspect ratio exceeds 1.

IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS (2022)

Article Engineering, Multidisciplinary

In-situ triaxial residual magnetic field measurement based on optically-detected electron paramagnetic resonance of spin-polarized potassium

Sheng Zou et al.

Summary: The approach presented utilizes EPR of spin-polarized K atoms to detect all three components of the residual magnetic field inside shielding, enabling the realization of a spin-exchange relaxation-free regime. Measurements are achieved through depopulation optical pumping and optically-detected peak of the K EPR spectrum. The EPR-based cross modulation method is employed to determine all three components of the residual field independently.

MEASUREMENT (2022)

Article Engineering, Multidisciplinary

A kilohertz bandwidth and sensitive scalar atomic magnetometer using an optical multipass cell

Shuguang Li et al.

Summary: This study presents a high-frequency ultraweak magnetic field measurement method using a scalar rubidium atomic magnetometer. The Faraday rotation signal is enhanced by a simplified optical multipass cell. By employing continuous or burst sampling mode and precise control pulse sequences, high contrast atomic spin projection noise and free induction decay signals were observed.

MEASUREMENT (2022)

Article Optics

Suppression of the magnetic noise response caused by elliptically polarized light in an optical rotation detection system

Bozheng Xing et al.

Summary: This study focuses on analyzing and suppressing the magnetic noise response in the optical rotation detection system (ORDS) of atomic magnetometers. The research reveals the close relationship between the responses to magnetic noise and the DC magnetic field. By calculating the values of the DC magnetic fields using specific frequency points, referred to as "break points," it is possible to effectively suppress the magnetic noise responses. Through residual magnetic field compensation, the sensitivity of the ORDS is significantly improved, approximately two times higher at a frequency range of 10-20 Hz.

OPTICS EXPRESS (2022)

Article Optics

Analysis of effects of magnetic field gradient on atomic spin polarization and relaxation in optically pumped atomic magnetometers

Xiujie Fang et al.

Summary: The effects of magnetic field gradient on the sensitivity improvement of optical pumping magnetometers (OPMs) under extremely low magnetic field conditions were investigated. By modifying the magnetic field gradient relaxation model, the study determined the gradient relaxation time and spin polarizations, and verified the accuracy of the improved model through experimental results. The study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.

OPTICS EXPRESS (2022)

Article Physics, Applied

Microwave magnetic field strength imaging based on Rabi resonance with alkali-atom vapor cell

Lang Chen et al.

Summary: In this study, an alternative Rabi resonance-based microwave imaging technique using a digital micromirror device and an alkali atomic cell is proposed. The experimental results quantitatively describe the distribution of the microwave field and agree with the absorption imaging results. This technique can also analyze and measure the relaxation rate in an atomic vapor cell and provides a SI-traceable imaging approach for the microwave magnetic field. Its simple architecture holds great potential for the development of compact/miniature microwave field sensors.

APPLIED PHYSICS LETTERS (2022)

Article Engineering, Electrical & Electronic

Design of Self-Shielded Uniform Magnetic Field Coil via Modified Pigeon-Inspired Optimization in Miniature Atomic Sensors

Jing Wang et al.

Summary: This article introduces a modified pigeon-inspired optimization method for designing self-shielded uniform magnetic field coils, which provides innovation in miniature atomic sensors. The proposed coil system, consisting of circular coil pairs on two coaxial cylinder surfaces, offers a highly uniform magnetic field at the coil center and rapidly attenuates external field. By transforming the design into a nonlinear objective optimization problem with constraints, the algorithm presented in this study enables obtaining geometric parameters of the coils without solving closed-form equations through purely numerical methods. The method introduces parallel competition and hierarchical search strategy to accelerate convergence speed and prevent local optimal values, demonstrating accuracy, effectiveness, and convergence stability through comparative experiments with traditional design methods. The theoretical comparison also shows significant improvement in coil uniformity and self-shielding effect compared to the Lee-Whiting coil, benefiting the miniaturization of atomic sensors.

IEEE SENSORS JOURNAL (2021)

Article Physics, Multidisciplinary

Search for axion-like dark matter with spin-based amplifiers

Min Jiang et al.

Summary: This study reports on the search for axion-like dark matter using a quantum sensor with enhanced potential signals. By utilizing hyperpolarized long-lived nuclear spins as pre-amplifiers, the study achieved ultrahigh magnetic sensitivity and constrained the parameter space of interactions between nucleons and axion-like particles. The experiment significantly improved on previous laboratory constraints and exceeded bounds from astrophysical observations.

NATURE PHYSICS (2021)

Article Engineering, Electrical & Electronic

A Magnetic Field In-Situ Measurement Method of the Heating Film in Atomic Sensors

Xiaoyang Liang et al.

Summary: The in-situ magnetic field measurement method can accurately reflect the influence of the heating film on the atomic sensor, avoiding distance errors present in the independent magnetometer method. This method provides a more precise evaluation of the magnetic field suppression effect and can be used to further enhance the performance of the heating film.

IEEE SENSORS JOURNAL (2021)

Article Physics, Multidisciplinary

Search for Axionlike Dark Matter Using Solid-State Nuclear Magnetic Resonance

Deniz Aybas et al.

Summary: Experimental search for ultralight axionlike dark matter in the mass range 162-166 neV is conducted using Cosmic Axion Spin Precession Experiment based on precision measurement of nuclear magnetic resonance, setting upper bounds for certain couplings in the frequency range. The study demonstrates the feasibility of using solid-state nuclear magnetic resonance to search for axionlike dark matter in the neV mass range.

PHYSICAL REVIEW LETTERS (2021)

Proceedings Paper Engineering, Electrical & Electronic

Modeling of the Transient Behavior of a Nuclear Magnetic Resonance Gyroscope

Riccardo Cipolletti et al.

Summary: This study introduces a concept, modeling, and parameter optimization for a spin-based navigation-grade gyroscope, bridging the gap between high precision optical and low-cost MEMS gyroscopes. A numerical solution is used to consider all relevant magnetic fields and back-interactions to better understand the transient behavior of the sensor signal.

2021 IEEE SENSORS (2021)

Article Optics

Magnetic-field-inhomogeneity-induced transverse-spin relaxation of gaseous 129Xe in a cubic cell with a stem

Deok-Young Lee et al.

Summary: In this study, the transverse-spin relaxations of Xe-129 due to diffusion in the presence of magnetic-field gradients were investigated in sub-cm sized cubic-like atomic gas cells with stems. The measured transverse-spin-relaxation rates in different cell sizes were used to extract the quadratic coefficients with respect to magnetic-field gradients. The effect of stem dimensions on the relaxation rate was analyzed, revealing the invariant ratio under scaling in cell size and diffusion coefficient changes.

PHYSICAL REVIEW A (2021)

Article Optics

Spin-polarization dependence of the Rb-Xe spin-exchange optical pumping process

Bowen Song et al.

Summary: In this experiment, the dependence of spin exchange rate on the intensity of pumping light was measured at different temperatures under low magnetic fields for the Rb-Xe spin-exchange optical pumping process. It was demonstrated that the spin-exchange rate decreases as the Rb spin polarization increases, in agreement with theoretical predictions. The three spin exchange and relaxation mechanisms were found to have comparable magnitudes in the measurements, providing a comprehensive confirmation of the physical picture of the process.

PHYSICAL REVIEW A (2021)

Article Optics

Herriott-cavity-assisted closed-loop Xe isotope comagnetometer

C-P Hao et al.

Summary: This paper presents a Herriott-cavity-assisted closed-loop Xe isotope gas comagnetometer that utilizes a passive method to improve system stability and sensitivity. The system has wide applications in precision measurements.

PHYSICAL REVIEW A (2021)

Article Physics, Applied

Three-axis atomic magnetometer for nuclear magnetic resonance gyroscopes

Xuyang Qiu et al.

APPLIED PHYSICS LETTERS (2020)

Article Engineering, Electrical & Electronic

Isotope Shift of Nuclear Magnetic Resonances in 129Xe and 131Xe Caused by Spin-Exchange Pumping by Alkali Metal Atoms

Vladimir I. Petrov et al.

IEEE SENSORS JOURNAL (2020)

Article Optics

Lock-in-detection in 87Rb-129Xe/131Xe atom spin gyroscopes

Sangkyung Lee et al.

JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS (2020)

Article Nanoscience & Nanotechnology

Improved compensation and measurement of the magnetic gradients in an atomic vapor cell

Xiang Zhan et al.

AIP ADVANCES (2020)

Article Physics, Applied

Pump beam influence on spin polarization homogeneity in the nuclear magnetic resonance gyroscope

Jia Yuchen et al.

JOURNAL OF PHYSICS D-APPLIED PHYSICS (2019)

Article Engineering, Multidisciplinary

Research on case rotating modulation for nuclear-spin comagnetometer in space-stable INS

Qingzhong Cai et al.

MEASUREMENT (2019)

Article Computer Science, Information Systems

Design of Highly Uniform Magnetic Field Coils Based on a Particle Swarm Optimization Algorithm

Wenfeng Wu et al.

IEEE ACCESS (2019)

Article Physics, Multidisciplinary

3He-129Xe Comagnetometery using 87Rb Detection and Decoupling

M. E. Limes et al.

PHYSICAL REVIEW LETTERS (2018)

Article Biochemical Research Methods

Comparison of operation modes for spin-exchange optically-pumped spin oscillators

Zhiguo Wang et al.

JOURNAL OF MAGNETIC RESONANCE (2017)

Article Nanoscience & Nanotechnology

A method for calibrating coil constants by using the free induction decay of noble gases

Linlin Chen et al.

AIP ADVANCES (2017)

Article Biochemical Research Methods

Rabi resonance in spin systems: Theory and experiment

Kelvin J. Layton et al.

JOURNAL OF MAGNETIC RESONANCE (2014)

Article Physics, Multidisciplinary

Constraints on Spin-Dependent Short-Range Interaction between Nucleons

K. Tullney et al.

PHYSICAL REVIEW LETTERS (2013)

Article Physics, Multidisciplinary

Collisional 3He and 129Xe Frequency Shifts in Rb-Noble-Gas Mixtures

Z. L. Ma et al.

PHYSICAL REVIEW LETTERS (2011)

Article Physics, Multidisciplinary

Nuclear spin gyroscope based on an atomic comagnetometer

TW Kornack et al.

PHYSICAL REVIEW LETTERS (2005)