Detection and correction of patient motion in dynamic O-15-water PET MPI

Related references

Note: Only part of the references are listed.
Editorial Material Cardiac & Cardiovascular Systems

Data-driven motion correction rescues interpretation of rubidium PET scan with extreme breathing artifacts

David Gao et al.

JOURNAL OF NUCLEAR CARDIOLOGY (2023)

Article Cardiac & Cardiovascular Systems

Automated dynamic motion correction improves repeatability and reproducibility of myocardial blood flow quantification with rubidium-82 PET imaging

Justen Choueiry et al.

Summary: This study evaluated the effect of automatic motion correction on test-retest repeatability and inter-observer variability in a clinically relevant population. The results showed that automatic motion correction improved test-retest repeatability and reduced differences between observers.

JOURNAL OF NUCLEAR CARDIOLOGY (2023)

Article Cardiac & Cardiovascular Systems

Influence of patient motion on quantitative accuracy in cardiac 15O-water positron emission tomography

Jonny Nordstrom et al.

Summary: Patient motion can affect the quantitative accuracy of cardiac O-15-water PET/CT scans, but at typical levels, the effects are similar to or only slightly higher than inter-observer variability, with likely negligible downstream clinical impacts.

JOURNAL OF NUCLEAR CARDIOLOGY (2022)

Article Cardiac & Cardiovascular Systems

The prevalence of image degradation due to motion in rest-stress rubidium-82 imaging on a SiPM PET-CT system

Ian S. Armstrong et al.

Summary: The study found that motion degradation is present in almost half of all cardiac PET images, with the DDMC algorithm being a robust tool for predicting and correcting image degradation. The DF metric effectively predicted image degradation.

JOURNAL OF NUCLEAR CARDIOLOGY (2022)

Editorial Material Cardiac & Cardiovascular Systems

Moving forward with motion reduction, detection and correction in cardiac PET

Ernest V. Garcia et al.

JOURNAL OF NUCLEAR CARDIOLOGY (2022)

Article Cardiac & Cardiovascular Systems

Effect of PET-CT misalignment on the quantitative accuracy of cardiac 15O-water PET

Jonny Nordstrom et al.

Summary: The effect of PET CT misalignment on the quantitative accuracy of cardiac O-15-water PET was assessed in this study. The study found that blood flow rates (MBF) were only slightly affected, while uptake rates (MBFt) showed larger effects.

JOURNAL OF NUCLEAR CARDIOLOGY (2022)

Article Cardiac & Cardiovascular Systems

Assessment of motion correction in dynamic rubidium-82 cardiac PET with and without frame-by-frame adjustment of attenuation maps for calculation of myocardial blood flow

Ian S. Armstrong et al.

Summary: Patient motion during pharmacological stressing can affect myocardial blood flow estimated from dynamic PET. This study evaluated a motion correction algorithm for dynamic rubidium data, finding that motion correction is beneficial for future MBF software updates, while adjustment of the PET attenuation map has minimal impact. Assessment of the uniformity of spill-over plots is a useful visual aid for verifying motion correction techniques.

JOURNAL OF NUCLEAR CARDIOLOGY (2021)

Article Cardiac & Cardiovascular Systems

Short-term repeatability of myocardial blood flow using 82Rb PET/CT: The effect of arterial input function position and motion correction

Yuka Otaki et al.

Summary: The study demonstrated that motion correction (MC) significantly improved the test-retest repeatability between operators and between scans. The results showed that MBF obtained after MC with LV-AIF were comparable, while MBFs after MC and LA-AIF were significantly reduced.

JOURNAL OF NUCLEAR CARDIOLOGY (2021)

Article Computer Science, Interdisciplinary Applications

Automatic Inter-Frame Patient Motion Correction for Dynamic Cardiac PET Using Deep Learning

Luyao Shi et al.

Summary: In this study, an automatic deep learning-based motion correction method for dynamic cardiac PET imaging was developed to detect and correct inter-frame rigid translational motion. The proposed DeepMC showed superior performance compared to conventional registration-based methods and other convolutional neural networks in terms of motion estimation accuracy and MBF quantification accuracy. Additionally, once trained, the DeepMC method was faster than registration-based methods and easily integrated into clinical workflows.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2021)

Article Cardiac & Cardiovascular Systems

Data-driven, projection-based respiratory motion compensation of PET data for cardiac PET/CT and PET/MR imaging

Martin Lyngby Lassen et al.

JOURNAL OF NUCLEAR CARDIOLOGY (2020)

Article Cardiac & Cardiovascular Systems

Reducing motion-correction-induced variability in 82rubidium myocardial blood-flow quantification

Alexis Poitrasson-Riviere et al.

JOURNAL OF NUCLEAR CARDIOLOGY (2020)

Article Cardiac & Cardiovascular Systems

Blood pool and tissue phase patient motion effects on 82rubidium PET myocardial blood flow quantification

Benjamin C. Lee et al.

JOURNAL OF NUCLEAR CARDIOLOGY (2019)

Article Cardiac & Cardiovascular Systems

No need for frame-wise attenuation correction in dynamic Rubidium-82 PET for myocardial blood flow quantification

J. D. van Dijk et al.

JOURNAL OF NUCLEAR CARDIOLOGY (2019)

Article Cardiac & Cardiovascular Systems

Impact of regadenoson-induced myocardial creep on dynamic Rubidium-82 PET myocardial blood flow quantification

S. S. Koenders et al.

JOURNAL OF NUCLEAR CARDIOLOGY (2019)

Article Cardiac & Cardiovascular Systems

Clinical Quantification of Myocardial Blood Flow Using PET: Joint Position Paper of the SNMMI Cardiovascular Council and the ASNC

Venkatesh L. Murthy et al.

JOURNAL OF NUCLEAR CARDIOLOGY (2018)

Review Cardiac & Cardiovascular Systems

Motion Correction and Its Impact on Absolute Myocardial Blood Flow Measures with PET

Marina Piccinelli et al.

CURRENT CARDIOLOGY REPORTS (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging

Chad R. R. N. Hunter et al.

MEDICAL PHYSICS (2016)

Article Cardiac & Cardiovascular Systems

Effects of patient movement on measurements of myocardial blood flow and viability in resting 15O-water PET studies

Kazuhiro Koshino et al.

JOURNAL OF NUCLEAR CARDIOLOGY (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET/CT scanner

Hendrik J. Harms et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2011)

Article Cardiac & Cardiovascular Systems

Cardiac positron emission tomography: myocardial perfusion and metabolism in clinical practice

Paul Knaapen et al.

CLINICAL RESEARCH IN CARDIOLOGY (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Motion detection and correction for dynamic 15O-water myocardial perfusion PET studies

A Naum et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2005)