4.6 Article

Low-Dose vs High-Dose Drug-Coated Balloon for Symptomatic Femoropopliteal Artery Disease The PROSPECT MONSTER Study Outcomes

Journal

JACC-CARDIOVASCULAR INTERVENTIONS
Volume 16, Issue 21, Pages 2655-2665

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2023.08.022

Keywords

drug-coated balloon; femoropopliteal artery; endovascular therapy; propensity score matching

Ask authors/readers for more resources

Randomized trials have shown that second-generation low-dose drug-coated balloons (LD-DCBs) and first-generation high-dose drug-coated balloons (HD-DCBs) have comparable outcomes. This study compared the outcomes between LD-DCBs and HD-DCBs in patients with symptomatic femoropopliteal artery disease. The results suggest that LD-DCBs are as effective and safe as HD-DCBs in medically complex populations.
BACKGROUND Randomized trials have shown comparable outcomes between second-generation low-dose drug-coated balloons (LD-DCBs) and first-generation high-dose drug-coated balloons (HD-DCBs); but the trial patients had low clinical complexity, and there were no comparisons in medically complex populations.OBJECTIVES The aim of this study was to compare outcomes between an LD-DCB (Ranger; 2.0 mg/mm(2)) and an HD-DCB (IN.PACT; 3.5 mg/mm(2)) in patients with symptomatic femoropopliteal artery disease.METHODS PROSPECT MONSTER (Prospective Comparison of Second-Generation Low-Dose Drug-Coated Balloon With High-Dose Drug-Coated Balloon) was a prospective, multicenter, nonrandomized trial that prospectively collected data from 581 patients who underwent endovascular therapy with the LD-DCB (n = 370) or the HD-DCB (n = 211) for symptomatic femoropopliteal artery disease (Rutherford classes 2-5). The primary outcome was the 1-year primary patency of the LD-DCB in comparison with that of the HD-DCB, as evaluated using propensity score matching. The incidence of impaired flow after drug-coated balloon application was also evaluated.RESULTS Propensity score matching extracted 163 pairs (358 and 163 patients in the LD-DCB and HD-DCB groups, respectively), with no significant intergroup difference in baseline characteristics. The 1-year primary patency rates in the matched population were similar between the LD-DCB and HD-DCB groups (87.0% [95% CI: 82.5%-91.7%] vs 81.3% [95% CI: 74.8%-88.5%]; HR: 0.93; 95% CI: 0.55-1.59; P = 0.79), as was the incidence of impaired flow (13.6% vs 9.8%; OR: 1.46; 95% CI: 0.78-2.73; P = 0.24). No baseline characteristics had any significant interaction effects on the association of the LD-DCB vs the HD-DCB and 1-year restenosis risk. CONCLUSIONS LD-DCBs demonstrate efficacy and safety comparable with HD-DCBs in patients with complex clinical backgrounds, suggesting that drug-coated balloon treatment using a lower dose may be possible.(c) 2023 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available