4.1 Article

Evaluating the Feasibility and Accuracy of Digitizing a Maxillary Defect Model Simulating Various Trismus Conditions

Journal

INTERNATIONAL JOURNAL OF PROSTHODONTICS
Volume 36, Issue 3, Pages 366-374

Publisher

QUINTESSENCE PUBLISHING CO INC
DOI: 10.11607/ijp.7842

Keywords

-

Ask authors/readers for more resources

The purpose of this study was to compare the feasibility and accuracy of using intraoral scanners to digitize a maxillary defect model simulating various trismus conditions. Four intraoral scanners were used to digitize the model, and the scans were compared for surface area, precision, and trueness. The results showed significant differences in surface area, precision, and trueness among the scanners and between the trismus conditions. However, digitization was found to be feasible and accurate with all scanners, despite differences in trueness and precision. The smaller scanned surface area in severe trismus was due to lack of data on the defect site.
Purpose: To compare the feasibility and accuracy of using intraoral scanners to digitize a maxillary defect model simulating various trismus conditions. Materials and Methods: Four intraoral scanners were used to digitize a maxillary defect model simulating four different degrees of trismus (mouth opening = 10, 20, 30, and 40 mm), and the scanned areas were compared. The scans were also superimposed on each other for precision analysis and on reference data for trueness analysis using 3D evaluation software. Two-way ANOVA was used to compare area, precision, and trueness among scanners and among conditions. Results: The surface area for which 3D data were obtained by the intraoral scanners ranged from 2,672 to 6,613 mm2. Significant differences were observed between the scanners (P < .001) and between the trismus conditions (P < .001), with a smaller scanned surface area in severe trismus (10 mm). Trueness ranged from 0.033 to 0.301 mm, and precision from 0.022 to 0.397 mm. Significant differences in trueness and precision values were found among the scanners (P = .001 and P = .001, respectively), but not the trismus conditions (P = .260 and P = .075, respectively). Conclusion: Although trueness and precision differed between intraoral scanners, digitization of the maxillectomy model simulating various trismus conditions appears to be feasible from the perspective of accuracy with all of the scanners used. The smaller scanned surface area in the severe trismus condition was due to lack of data on the defect site in that condition. Int J Prosthodont 2023;36:366-374. doi: 10.11607/ijp.7842

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available