4.6 Article

Comparison between multimodality imaging approaches for measurement of the tricuspid annulus in severe tricuspid regurgitation

Journal

INTERNATIONAL JOURNAL OF CARDIOLOGY
Volume 383, Issue -, Pages 151-158

Publisher

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ijcard.2023.03.027

Keywords

Tricuspid regurgitation; Tricuspid annulus diameter; Multimodal imaging; Echocardiography; Computed tomography

Ask authors/readers for more resources

This study compared the differences in tricuspid annulus measurements between echocardiography and computed tomography. The results showed that the long-axis dimensions measured by three-dimensional echocardiography were most similar to the diameters measured by computed tomography.
Background: Tricuspid valve (TV) sizing is crucial for surgical or interventional procedures planning. Imaging TV is frequently challenging and often requires multimodal imaging techniques. Computed tomography (CT) is the gold standard for sizing. The authors compared measurements of the tricuspid annulus (TA) acquired using echocardiography and CT.Methods: Thirty-six patients with severe symptomatic tricuspid regurgitation were included in this retrospective analysis. During mid-diastole, the maximal two-dimensional (2D) TA diameter was directly measured in multiple views using transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE). Threedimensional (3D) TA size was assessed using cross-sectional long-axis and short-axis diameters, areas, and perimeters measured in the projected plane. The TA diameter was quantified by the perimeter measured on the CT images (CT imaging_indirect) and compared with echocardiography measurements. Tenting height and tenting area were also measured using TTE at mid systole.Results: The long-axis dimensions measured using 3DTEE (3DTEE_direct) best correlated with the TA diameter (CT imaging_indirect) (R = 0.851, P = 0.0001) and the least discrepancies (difference 1.2 +/- 2.4 mm, P = 0.012). The TA diameters quantified by the perimeters measured using 3DTEE (3DTEE_indirect) were smaller than the CT values (difference 2.5 +/- 2.5 mm, P = 0.0001). The maximal dimensions directly measured by 2DTEE (2DTEE_direct) were modestly correlated with the CT values. Overall, the maximal dimensions by TTE_direct were less reliable than those by CT. TA eccentricity index correlated with the maximal tenting height and area.Conclusion: The patients with severe tricuspid regurgitation had a dilated and circular annulus. The long-axis TA dimensions (3DTEE_direct) were similar to the diameters (CT imaging_indirect).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available