4.8 Article

Power Sharing and ZSCC Elimination for Parallel T-Type Three-Level Rectifiers Based on Model-Free Predictive Control

Journal

IEEE TRANSACTIONS ON POWER ELECTRONICS
Volume 38, Issue 10, Pages 12166-12179

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TPEL.2023.3295351

Keywords

Model-free predictive control with multiobjective optimization (MOO-MFPC); neutral-point (NP) voltage balance; parallel three-level T-type rectifiers (3LT2Rs)

Ask authors/readers for more resources

This article proposes a model-free predictive control method with multiobjective optimization for two parallel three-level T-type rectifiers. It does not rely on precise circuit parameters and models, and can achieve multiobjective optimization control without weighting factors.
Due to its outstanding merits, such as quick response, multiobjective optimization, and simple principle, model predictive control (MPC) has been widely used in power converters and motor-drive systems. However, MPC highly relies on the precise circuit parameters and control models, and cannot be used in unknown circuit relationships. To solve this issue, this article presents a model-free predictive control (MFPC) with multiobjective optimization (MOO) for two parallel three-level T-type rectifiers (3LT2Rs). First, the main control objectives of 3LT(2)Rs are analyzed, and the overall control scheme of the double closed-loop control is established. Second, based on the mathematical model of the parallel system, an MOO-MFPC for neutral-point voltage balance, current tracking, and zero-sequence circulating current elimination is proposed, which does not require any prior knowledge of the circuit parameters and circuit models, and it can achieve MOO control without weighting factors and its priority is not fixed. To solve the current difference updating stagnation problem in MOO-MFPC, a synchronous updating method is designed, which is faster than that of a single rectifier. Finally, the proposed method is tested on a hardware prototype of a 10-kW and a 5-kW parallel rectifier. Numerous experimental results demonstrate the merits of this method over the existing methods under several typical scenarios.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available