4.8 Article

A Simple Technique Linearizing and Decoupling DC-Link Voltage Control From Source Nonlinearity in Single-Stage Photovoltaic Inverters

Journal

IEEE TRANSACTIONS ON POWER ELECTRONICS
Volume 38, Issue 9, Pages 11652-11663

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TPEL.2023.3290958

Keywords

Cascaded control; dc-ac power conversion; photovoltaic (PV) power systems; photovoltaic voltage control; transient response

Ask authors/readers for more resources

This article investigates the influence of nonlinear behavior of photovoltaic (PV) sources on the dc voltage regulation of single-stage single-phase grid-connected inverters. The analysis reveals two issues: undesired strong coupling between regulation transient performance and PV source operating point, and possible instability arising when the PV source operates on the left-hand side of its maximum power point (MPP). To solve these problems, the idea to add the PV power feedforward signal to the output of the dc voltage controller is proposed, resulting in improved PV voltage regulation performance and stable dc voltage control dynamics.
The nonlinear behavior of photovoltaic (PV) sources can deteriorate the performance of PV inverters if their control system is not designed carefully. This article investigates the PV source influence on the dc voltage regulation of single-stage single-phase grid-connected inverters. The analysis reveals two issues: undesired strong coupling between regulation transient performance and PV source operating point, and possible instability arising when the PV source operates on the left-hand side of its maximum power point (MPP). To eradicate these issues, the idea to add the PV power feedforward signal to the output of the dc voltage controller is applied. This action cancels the nonlinearity induced by the source, responsible for poor PV voltage regulation performance, resulting in large-signal linear and stable dc voltage control dynamics. The benefit is twofold. First, the dc voltage transient response is desirably decoupled from the PV source operating condition (left-hand side of MPP, MPP, and right-hand side of MPP). Second, the possible instability occurring at the left-hand side of the MPP is eliminated. The research findings are supported by simulations and experimental results extracted out of a grid-connected inverter fed by a PV emulator. Through this testbed, the proposed controller is compared against conventional and emerging dc voltage control schemes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available