4.4 Article

Experimental Study on the Critical Current Properties of Flexible Nb3Al Superconducting Wires in Cryocooler System

Journal

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TASC.2023.3258911

Keywords

Ultrafine Nb3Al wire; conduction cooling; critical current characteristics; I-c measurement method

Ask authors/readers for more resources

Jelly-rolled Nb/Al composite monofilament Nb3Al superconducting wires with an outer diameter of 30 μm and multi-stranded Nb3Al wires have been successfully fabricated by NIMS in Japan. Temperature dependence of the critical current of Nb3Al wires in a cryocooler system for superconducting applications cooled by conduction cooling method is necessary. The critical current properties of single and multi-stranded ultrafine Nb3Al superconducting sample wires with different outer diameter were evaluated using the current sweep method and constant current method.
In recent years, Jelly-rolled Nb/Al composite monofilament Nb3Al superconducting wires with an outer diameter of 30 mu m, and multi-stranded Nb3Al wires were successfully fabricated by NIMS in Japan. So, it is necessary to measure the temperature dependence of the critical current of Nb3Al wires in cryocooler system for development of superconducting applications cooled by conduction cooling method. The single and multi-stranded ultrafine Nb3Al superconducting sample wires with different outer diameter were prepared to evaluate the critical current properties. The critical currents of sample wires were evaluated by the current sweep method and constant current method. In this study, the sample wires were soldered to the copper wire to prevent burnout of the sample wire during critical current measurements. Therefore, the amount of current shunted to the copper wire was estimated to accurately evaluate the critical current of the superconducting wire. Also, the critical current of Nb3Al wires due to bending strain (bending radius of 5 to 15 mm) was experimentally investigated. From the critical current measurement results of Nb3Al wires with different cross-sectional structures, it was confirmed that the superconducting properties of the wires were improved by reducing the wire diameter. It was shown that the critical current density of the developed Nb3Al wire is lower than that of REBCO wire, but higher than that of commercial NbTi and Nb3Sn wires.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available