4.4 Review

Worsening tricuspid regurgitation associated with permanent pacemaker and implantable cardioverter-defibrillator implantation: A systematic review and meta-analysis of more than 66,000 subjects

Related references

Note: Only part of the references are listed.
Article Cardiac & Cardiovascular Systems

Leadless left ventricular stimulation with WiSE-CRT System - Initial experience and results from phase I of SOLVE-CRT Study (nonrandomized, roll-in phase)

Toshimasa Okabe et al.

Summary: This study presents the short-term outcomes of the WiSE-CRT system in centers with no prior implanting experience. The results show a high success rate of LV endocardial electrode placement, with favorable clinical responses in heart failure symptoms and significant LV reverse remodeling.

HEART RHYTHM (2022)

Review Cardiac & Cardiovascular Systems

Tricuspid regurgitation in His bundle pacing: A systematic review

Syed Muhammad Jawad Zaidi et al.

Summary: This systematic review aimed to explore the association of new tricuspid regurgitation (TR) and its quantification in patients undergoing His bundle pacing (HBP). The review included 10 studies and found that HBP can improve TR grade.

ANNALS OF NONINVASIVE ELECTROCARDIOLOGY (2022)

Review Medicine, General & Internal

The PRISMA 2020 statement: an updated guideline for reporting systematic reviews

Matthew J. Page et al.

Summary: The PRISMA statement was designed to help systematic reviewers transparently report the purpose, methods, and findings of their reviews. The updated PRISMA 2020 statement includes new reporting guidance, a 27-item checklist, an abstract checklist, and revised flow diagrams for reviews.

BMJ-BRITISH MEDICAL JOURNAL (2021)

Article Cardiac & Cardiovascular Systems

Echocardiographic assessment of tricuspid regurgitation and pericardial effusion after cardiac device implantation

Katarzyna Wiechecka et al.

CARDIOLOGY JOURNAL (2020)

Review Cardiac & Cardiovascular Systems

New Percutaneous Options for Tricuspid Intervention: How to Identify the Good Clinical Candidate

Alessandra Laricchia et al.

FRONTIERS IN CARDIOVASCULAR MEDICINE (2020)

Article Cardiac & Cardiovascular Systems

Impact of Leadless Pacemaker Therapy on Cardiac and Atrioventricular Valve Function Through 12 Months of Follow-Up

Niek E. G. Beurskens et al.

CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY (2019)

Article Cardiac & Cardiovascular Systems

Incidence and predictors of moderate to severe tricuspid regurgitation after dual-chamber pacemaker implantation

Min Soo Cho et al.

PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY (2019)

Article Psychiatry

How to perform a meta-analysis with R: a practical tutorial

Sara Balduzzi et al.

EVIDENCE-BASED MENTAL HEALTH (2019)

Article Cardiac & Cardiovascular Systems

Effect of ventricular pacing lead position on tricuspid regurgitation: A randomized prospective trial

J. William Schleifer et al.

HEART RHYTHM (2018)

Review Cardiac & Cardiovascular Systems

Severe tricuspid regurgitation due to interactions with right ventricular permanent pacemaker or defibrillator leads

Cory R. Trankle et al.

PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY (2018)

Article Cardiac & Cardiovascular Systems

Pacemaker-induced tricuspid regurgitation is uncommon immediately post-implantation

Daniel P. Rothschild et al.

JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY (2017)

Review Cardiac & Cardiovascular Systems

Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation

James D. Chang et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2017)

Article Cardiac & Cardiovascular Systems

Tricuspid Regurgitation and Mortality in Patients With Transvenous Permanent Pacemaker Leads

Francesca N. Delling et al.

AMERICAN JOURNAL OF CARDIOLOGY (2016)

Article Cardiac & Cardiovascular Systems

Clinical utility of three-dimensional echocardiography in the evaluation of tricuspid regurgitation induced by implantable device leads

Yan Cheng et al.

ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES (2016)

Article Cardiac & Cardiovascular Systems

Tricuspid Regurgitation Following Implantation of Endocardial Leads: Incidence and Predictors

Regina C. Lee et al.

PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY (2015)

Article Cardiac & Cardiovascular Systems

Impact of Implantable Transvenous Device Lead Location on Severity of Tricuspid Regurgitation

Karima Addetia et al.

JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY (2014)

Article Cardiac & Cardiovascular Systems

3D Echocardiographic Location of Implantable Device Leads and Mechanism of Associated Tricuspid Regurgitation

Anuj Mediratta et al.

JACC-CARDIOVASCULAR IMAGING (2014)

Article Cardiac & Cardiovascular Systems

Tricuspid Regurgitation Following Implantation of a Pacemaker/Cardioverter-Defibrillator

Maha A. Al-Mohaissen et al.

CURRENT CARDIOLOGY REPORTS (2013)

Review Cardiac & Cardiovascular Systems

Prevalence and Mechanism of Tricuspid Regurgitation following Implantation of Endocardial Leads for Pacemaker or Cardioverter-Defibrillator

Maha A. Al-Mohaissen et al.

JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY (2012)

Article Medicine, General & Internal

Measuring inconsistency in meta-analyses

JPT Higgins et al.

BMJ-BRITISH MEDICAL JOURNAL (2003)