4.4 Article

Inaccurate quantitation of palmitate in metabolomics and isotope tracer studies due to plastics

Journal

METABOLOMICS
Volume 12, Issue 9, Pages -

Publisher

SPRINGER
DOI: 10.1007/s11306-016-1081-y

Keywords

Isotope labeling; Lipidomics; Palmitate; Plastic contamination; Stearate

Funding

  1. National Institutes of Health [R01 ES022181, R21 CA191097, R01 HL118639-03]
  2. Alfred P. Sloan Foundation
  3. Camille & Henry Dreyfus Foundation
  4. Pew Scholars Program in the Biomedical Sciences

Ask authors/readers for more resources

Introduction Palmitate, the typical end product released from fatty acid synthase, is of interest to many researchers performing metabolomics. Although palmitate can be readily detected by using mass spectrometry, many metabolomic platforms involve the use of plastic consumables that introduce a competing background signal of palmitate. Objectives The goal of this study was to quantify palmitate contamination in metabolomics and isotope tracer studies and to examine the reliability of approaches for reducing error. Methods We measured the quantitative error introduced by palmitate contamination from 4 vendors of plastic consumables used in combination with several different extraction solvents. Results The background palmitate signal was as much as sixfold higher than the biological palmitate signal from 4 million 3T3-L1 cells. Importantly, the palmitate contamination signal was highly variable between plastic consumables (even within the same lot) and therefore could not be accurately removed by subtracting the background as measured from a blank. In addition to affecting relative and absolute quantitation, the palmitate background signal from disposable plastics also led to the underestimation of labeled palmitate in isotope tracer experiments. Conclusion When measuring palmitate standard solutions, the best results were obtained when glass vials and glass pipettes were used. However, much of the palmitate background signal could be eliminated by pre-rinsing plastic vials and plastic pipette tips with methanol prior to sample introduction. For isotope tracer studies, error could also be minimized by estimating palmitate enrichment from palmitoylcarnitine, which does not have a competing contamination signal from plastic consumables.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available