Journal
ENERGY
Volume 283, Issue -, Pages -Publisher
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2023.128999
Keywords
Smart window; Aerogel; Vacuum; Glazing; UK; Building; EnergyPlus; PDLC
Categories
Ask authors/readers for more resources
Globally, greenhouse gas emissions from the operational phase of buildings are a major contributor to climate change. Efforts are being made globally and nationally to reduce these emissions and achieve net zero energy buildings. This study evaluates the performance of advanced and smart/switchable windows in a low energy building in north Wales, UK, using experimental data and the International Glazing Database. The results indicate that PDLC-vacuum windows offer the greatest reduction in building energy consumption and are the best choice for achieving net zero energy buildings.
Globally, greenhouse gas emissions from the operational phase of buildings are significantly contributing towards climate change. Global and national efforts, through the Sustainable Development Goals and the UK's 2050 targets, aim to reduce these emissions with net zero energy buildings (NZEBs). A building's glazing plays a significant role in overall building energy consumption due to their traditionally 'leaky' nature. This study utilises experimental data from test cells and the International Glazing Database to evaluate the performance of advanced and smart/switchable windows on an existing low energy building (LEB) situated in north Wales, UK, as a step towards making the modelled building a NZEB. A number of glazing constructions were considered in this work; advanced window - vacuum, aerogel, vacuum-aerogel and smart window - PDLC, PDLC-aerogel and PDLC-vacuum, in their fixed and switching states. Results revealed that PDLC-vacuum offered the greatest reduction in building energy, yielding a theoretical U-value of 0.810-0.831 W/m2K and a G-value of 0.257-0.455. Despite its successes, it was notably susceptible to window orientation and window-to-wall ratio. Vacuum and aerogel glazing both offered similar energy savings, with the latter prone to overheating, stressing cooling loads. These advanced windows offered differing daylighting potential with vacuum able to meet 78% of useful daylight illuminance compared to aerogel's 60%. Given the prioritisation trilemma between heating, lighting and cooling needs of a building, PDLC-vacuum presents the best step towards a NZEB. As such, further efforts should concentrate on the development of a PDLC-vacuum window, maintaining smart window functionality and achieving low U-value for cold climates.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available