4.6 Article

Direct comparison of multiple computer-aided polyp detection systems

Related references

Note: Only part of the references are listed.
Article Gastroenterology & Hepatology

Usefulness of a novel computer-aided detection system for colorectal neoplasia: a randomized controlled trial

Antonio Z. Gimeno-Garcia et al.

Summary: This study tested the effectiveness of a CADe device called ENDO-AID (OIP-1) in clinical practice and found that it can improve the adenoma detection rate and detect diminutive and flat adenomas. This is helpful for the detection of colorectal neoplastic lesions.

GASTROINTESTINAL ENDOSCOPY (2023)

Article Gastroenterology & Hepatology

Performance of a new integrated computer-assisted system (CADe/CADx) for detection and characterization of colorectal neoplasia

Jochen Weigt et al.

Summary: The high accuracy demonstrated by CADe and CADx was similar to that of experts, suggesting the need for further evaluation in a clinical setting. When utilizing CAD, non-experts achieved a performance similar to experts, but with suboptimal specificity.

ENDOSCOPY (2022)

Article Gastroenterology & Hepatology

Effect of an artificial intelligence-based quality improvement system on efficacy of a computer-aided detection system in colonoscopy: a four-group parallel study

Liwen Yao et al.

Summary: This study evaluated the efficacy of combining the CADe and CAQ systems, showing that CAQ significantly improved the performance of CADe in improving the adenoma detection rate (ADR) in a four-group, parallel, controlled study.

ENDOSCOPY (2022)

Article Gastroenterology & Hepatology

Artificial intelligence and colonoscopy experience: lessons from two randomised trials

Alessandro Repici et al.

Summary: Artificial intelligence assistance during colonoscopy can increase adenoma detection rate (ADR) and related polyp parameters in less experienced examiners compared to the control group. The level of examiner experience does not play a significant role in determining ADR, as shown in this study.
Article Gastroenterology & Hepatology

Computer-Aided Detection Improves Adenomas per Colonoscopy for Screening and Surveillance Colonoscopy: A Randomized Trial

Aasma Shaukat et al.

Summary: This study evaluated the clinical benefit and safety of using a computer-aided detection (CADe) device in colonoscopy procedures. The results showed that the use of CADe device significantly increased adenoma detection rate without increasing the resection of non-neoplastic lesions.

GASTROENTEROLOGY (2022)

Article Gastroenterology & Hepatology

Development and evaluation of a deep learning model to improve the usability of polyp detection systems during interventions

Markus Brand et al.

Summary: This study developed and evaluated a convolutional neuronal network that can recognize instruments in endoscopic images, suppress distracting CADe detections, and reliably detect endoscopic interventions. The test results showed that the network achieved high accuracy and reliability in detecting visible instruments and can be used to reduce distracting CADe detections during endoscopic procedures.

UNITED EUROPEAN GASTROENTEROLOGY JOURNAL (2022)

Review Medicine, General & Internal

Current Status and Future Perspectives of Artificial Intelligence in Colonoscopy

Yu Kamitani et al.

Summary: Early endoscopic identification, resection, and treatment play a vital role in reducing the prevalence and mortality rate of colorectal cancer. Advances in endoscopic devices and artificial intelligence (AI) technology have improved the accuracy of detecting colorectal lesions and predicting their pathology. The use of AI in colonoscopy is becoming more prevalent, with AI devices already approved for clinical use. Expectations are growing for sophisticated AIs to provide high-level diagnostic performance regardless of the endoscopist's skill level.

JOURNAL OF CLINICAL MEDICINE (2022)

Article Gastroenterology & Hepatology

A video based benchmark data set (ENDOTEST) to evaluate computer-aided polyp detection systems

Daniel Fitting et al.

Summary: This study presents a video-based benchmark technique for evaluating computer-aided polyp detection (CADe) systems. The self-developed CADe system performs better than the commercial system in terms of detection and speed.

SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY (2022)

Article Gastroenterology & Hepatology

Automatic detection of colorectal neoplasia in wireless colon capsule endoscopic images using a deep convolutional neural network

Atsuo Yamada et al.

Summary: An AI system using deep learning was developed to automatically detect colorectal neoplasms in colon capsule endoscopy (CCE) images. The system showed good performance in terms of sensitivity, specificity, and accuracy after being trained and validated with around 16,000 tumor images.

ENDOSCOPY (2021)

Article Gastroenterology & Hepatology

Detection of colorectal adenomas with a real-time computer-aided system (ENDOANGEL): a randomised controlled study

Dexin Gong et al.

LANCET GASTROENTEROLOGY & HEPATOLOGY (2020)

Article Gastroenterology & Hepatology

Efficacy of Real-Time Computer-Aided Detection of Colorectal Neoplasia in a Randomized Trial

Alessandro Repici et al.

GASTROENTEROLOGY (2020)

Article Gastroenterology & Hepatology

The single-monitor trial: an embedded CADe system increased adenoma detection during colonoscopy: a prospective randomized study

Peixi Liu et al.

THERAPEUTIC ADVANCES IN GASTROENTEROLOGY (2020)

Article Gastroenterology & Hepatology

Frame-by-Frame Analysis of a Commercially Available Artificial Intelligence Polyp Detection System in Full-Length Colonoscopies

Markus Brand et al.

Summary: The study found that while the CADe system is reliable, it generates a large number of false-positive activations, most of which are very short. Suppressing short-term CADe activations can significantly reduce the number of false positives without impacting other performance metrics.