4.5 Article

Complications and radiographic changes after implantation of interspinous process devices: average eight-year follow-up

Journal

BMC MUSCULOSKELETAL DISORDERS
Volume 24, Issue 1, Pages -

Publisher

BMC
DOI: 10.1186/s12891-023-06798-9

Keywords

Coflex; Heterotopic ossification; Loosening; Osteolysis; Spinous process anastomosis

Ask authors/readers for more resources

This study aims to evaluate complications, clinical outcomes, and radiographic results following Coflex implantation. The majority of patients had improved clinical outcomes after surgery, but complications such as heterotopic ossification and Coflex loosening were observed in some cases.
Purpose This study aims to evaluate complications, clinical outcomes, and radiographic results following Coflex implantation.Methods We retrospectively studied 66 patients who had decompressive surgery combined with Coflex implantation to treat lumbar spinal stenosis. All imaging data were collected and examined for imaging changes. Clinical outcomes, included Oswestry Disability Index (ODI), back and leg visual analog scale (VAS) scores, were evaluated before surgery, six months after surgery and at the last follow-up. The number of complications occurring after five years of follow-up was counted. All reoperation cases were meticulously recorded.Results 66 patients were followed up for 5-14 years. The VAS and ODI scores were significantly improved compared with baseline. Heterotopic Ossification (HO) was detectable in 59 (89.4%). 26 (39.4%) patients had osteolysis at the contact site of Coflex with the spinous process. Coflex loosening was detected in 39 (60%) patients. Spinous process anastomosis was found in 34 (51.5%) patients. There was a statistically significant difference in the VAS score of back pain between patients with and without spinous process anastomosis. Nine cases of lumbar spinal restenosis were observed, and prosthesis fracture was observed in one case.Conclusion Our study identified various imaging changes after Coflex implantation, and majority of them did not affect clinical outcomes. The majority of patients had HO, but osteolysis and Coflex loosening were relatively rare. The VAS score for back pain of these patients was higher if they have spinous process anastomosis. After five-year follow-up, we found lumbar spinal restenosis and prosthesis fracture cases.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available