Journal
BIOMEDICAL SIGNAL PROCESSING AND CONTROL
Volume 88, Issue -, Pages -Publisher
ELSEVIER SCI LTD
DOI: 10.1016/j.bspc.2023.105354
Keywords
Blood pressure monitoring; Electrocardiography; Photoplethysmography; Gradient boosting regression tree; Grey wolf optimization
Categories
Ask authors/readers for more resources
In this study, a continuous blood pressure (BP) monitoring method based on random forest feature selection (RFFS) and a gray wolf optimization-gradient boosting regression tree (GWO-GBRT) prediction model was developed. The method extracted features from electrocardiogram (ECG) and photoplethysmography (PPG) signals, and employed RFFS to select sensitive features highly correlated with BP. A hybrid prediction model of gray wolf optimization (GWO) technique and gradient boosting regression tree (GBRT) algorithm was established to learn the relationship between BP and sensitive features. Experimental results demonstrated the effectiveness and advancement of the proposed method.
Blood pressure (BP) is an important indicator of a person's cardiovascular status, but accurate, continuous BP monitoring remains a challenge. To improve the monitoring performance of continuous BP using electrocardiogram (ECG) and photoplethysmography (PPG) signals, a continuous BP monitoring method based on random forest feature selection (RFFS) and a gray wolf optimization-gradient boosting regression tree (GWO-GBRT) prediction model is developed in this study. First, features in time, frequency, and time-frequency domains are extracted from PPG and ECG signals to supply comprehensive characteristics for BP monitoring. Then, the RFFS method is employed to select sensitive features highly correlated with BP from the candidate feature sets, which reduced redundant information and improved monitoring efficiency. Next, a hybrid prediction model of the gray wolf optimization (GWO) technique and gradient boosting regression tree (GBRT) algorithm is established to learn the dependency relationship between BP and sensitive features. And a new fitness function of GWO is designed to balance the monitoring accuracy and consistency. Finally, ablation and comparative experiments demonstrate the effectiveness and advancement of the proposed method, using the ECG and PPG signals of 150 people downloaded from the MIMIC-III database. The mean absolute error (MAE) and standard deviation (STD) of the proposed method in predicting systolic blood pressure were 2.91 mmHg and 3.97 mmHg, and those of diastolic blood pressure were 1.71 mmHg and 2.35 mmHg. Its monitoring accuracy has surpassed the Association for Advancement of Medical Instrumentation (AAMI) standard and reached the A level standard of the British Hypertension Society (BHS) protocol.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available