4.6 Article

New approaches for rapid setpoint determination and uninterrupted tracking in non-invasive continuous blood pressure monitoring based on volume-clamp method

Related references

Note: Only part of the references are listed.
Review Peripheral Vascular Disease

Continuous cuffless and non-invasive measurement of arterial blood pressure-concepts and future perspectives

Niklas Pilz et al.

Summary: This article introduces recent advances and future developments in the field of cuffless blood pressure measurement paradigms, with a focus on two main approaches: physiological understanding-based models and Deep Learning-based models. It proposes the idea of unifying the benefits of physiological understanding and Deep Learning techniques for cuffless beat-to-beat blood pressure estimation.

BLOOD PRESSURE (2022)

Article Multidisciplinary Sciences

A novel art of continuous noninvasive blood pressure measurement

Juergen Fortin et al.

Summary: The continuous noninvasive blood pressure measurement system CNAP2GO presents a potential breakthrough in patient monitoring, directly measuring blood pressure using volume control technique for integration in small wearable sensors. CNAP2GO demonstrated excellent blood pressure measurement performance during surgeries, with the capability to derive cardiac output and other hemodynamic variables. The system can self-calibrate and be miniaturized for wearable use, offering significant promise for blood pressure monitoring in clinical settings.

NATURE COMMUNICATIONS (2021)

Article Medicine, General & Internal

Accuracy of noninvasive continuous arterial pressure monitoring using ClearSight during one-lung ventilation

Sang-Wook Lee et al.

Summary: During one-lung ventilation, noninvasive arterial blood pressure monitoring with ClearSight shows acceptable agreement with the invasive method in terms of mean blood pressure and pulse rate.

MEDICINE (2021)

Article Engineering, Biomedical

Blood-pressure-waveform monitoring without interruptions due to changes in arterial compliance: The use of the vibrational and volume-clamp methods

Leonardo Casal et al.

Summary: This study successfully combined the vibrational method and volume-clamp method, demonstrating good linear correlation and agreement in volunteers. Furthermore, stability monitoring and adaptive adjustments were made to the control system, addressing the issue of instability in control.

MEDICAL ENGINEERING & PHYSICS (2021)

Article Peripheral Vascular Disease

Validation of finger blood pressure monitoring in children

Natalie D. Heeney et al.

BLOOD PRESSURE MONITORING (2019)

Editorial Material Critical Care Medicine

Non-invasive arterial pressure monitoring revisited

Frederic Michard et al.

INTENSIVE CARE MEDICINE (2018)

Review Critical Care Medicine

Perioperative myocardial injury and the contribution of hypotension

Daniel I. Sessler et al.

INTENSIVE CARE MEDICINE (2018)

Article Engineering, Biomedical

Monitoring of the central blood pressure waveform via a conformal ultrasonic device

Chonghe Wang et al.

NATURE BIOMEDICAL ENGINEERING (2018)

Article Engineering, Biomedical

Advanced Volume-Compensation Method for Indirect Finger Arterial Pressure Determination: Comparison with Brachial Sphygmomanometry

Kenta Matsumura et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2017)

Article Computer Science, Artificial Intelligence

Predicting hypertension without measurement: A non-invasive, questionnaire-based approach

Aiguo Wang et al.

EXPERT SYSTEMS WITH APPLICATIONS (2015)

Article Engineering, Biomedical

CONTINUOUS WRIST BLOOD PRESSURE MEASUREMENT WITH ULTRASOUND

S. Weber et al.

BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK (2013)

Article Anesthesiology

Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®

Jerson R. Martina et al.

ANESTHESIOLOGY (2012)

Article Physiology

Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method

Heiko Gesche et al.

EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY (2012)

Article Peripheral Vascular Disease

Validation of brachial artery pressure reconstruction from finger arterial pressure

Ilja Guelen et al.

JOURNAL OF HYPERTENSION (2008)

Article Medicine, General & Internal

Impact of high-normal blood pressure on the risk of cardiovascular disease.

RS Vasan et al.

NEW ENGLAND JOURNAL OF MEDICINE (2001)

Article Computer Science, Cybernetics

A model-based fuzzy logic controller with Kalman filtering for tracking mean arterial pressure

SH Liu et al.

IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART A-SYSTEMS AND HUMANS (2001)