4.7 Article

Performance evaluation of hot-wall condenser in a domestic refrigerator

Journal

APPLIED THERMAL ENGINEERING
Volume 233, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2023.121137

Keywords

Hot-wall condenser; Refrigerator; Heat transfer; Pipe form; Experimental tests; Heat transfer model

Ask authors/readers for more resources

This study investigates the heat transfer performance of a hot-wall condenser, which is affected by design parameters. The variation of pipe section form (O/D), a previously unexamined design parameter, was used. Twelve different condenser samples were manufactured with specified design parameters, and a simulation model was designed for comparison with experimental results. The results showed significant effects of the design parameters on the heat transfer rate of the condenser, including increases in heat transfer rate with larger condenser pipe diameter and variations in pipe pitch.
In this study, the heat transfer performance of a hot-wall condenser, which is affected by design parameters, is investigated. In this study, the pipe section form (O/D) variation, which has not been examined so far, is used as a design parameter for condenser performance. Incorporating the specified design parameters, 12 different condenser samples were manufactured. Additionally, a simulation model regarding with the thermal effects was designed for comparing the outputs of experimental results. The parameters are outer diameter of the condenser pipe (4.0 and 4.76 mm), condenser pipe pitch (20, 40, and 60 mm), the section form (O/D) of condenser pipe, and the refrigerant mass flow rate in flow. The results revealed significant findings regarding the impact of different design parameters on the heat transfer rate of the condenser. Specifically, increasing the condenser pipe diameter led to an average heat transfer rate increase of 8.9% and 5.2% by increasing flow rates as double, respectively. The pipe pitch was found to have a notable effect on the heat transfer rates, resulting in average increases of 213%, 47%, and 313% for the 20-40 mm, 40-60 mm, and 20-60 mm transitions, respectively. Specifically, the novel output is the transition from O-to-D pipe configuration, resulting in a maximum 3% increase in the total heat transfer rate.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available