4.8 Article

A novel characteristic-based degradation model of Li-ion batteries for maximum financial benefits of energy storage system during peak demand reductions

Journal

APPLIED ENERGY
Volume 343, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2023.121206

Keywords

SOH estimation; Degradation estimation; Li -ion battery; Peak demand reduction; Maximum net savings

Ask authors/readers for more resources

Lithium-ion batteries are commonly used in energy storage systems for grid services, providing financial and environmental benefits. A degradation model is needed to predict battery capacity losses and lifespan due to various factors. A characteristic-based degradation model is proposed and experimentally verified. Integrating with an idling degradation model, the model predicts the service lifespan and maximum financial benefit of an energy storage system under different conditions. The results show significant cost savings for both a university and a factory.
Lithium-ion (Li-ion) batteries are increasingly common in the energy storage system (ESS) to perform grid services such as peak demand reductions for financial and environmental benefits to customers, utility companies and governments. However, to realize the maximum financial benefits of ESS, it is necessary to develop a degradation model that can predict the battery capacity losses and lifespan due to intermittent charging current, discharging current, depth of discharge (DOD) and temperature with time. Therefore, a characteristic-based degradation model is proposed to predict the degradation and lifespan of the batteries based on the characteristics of charging current, discharging current, DOD and temperature with time. This model is verified experimentally based on the second-life batteries set up on the university campus. This model is then integrated with the idling degradation model to predict the service lifespan, optimum capacity and maximum financial benefit of ESS with either first or second-life batteries under different operating conditions. With the DOD of 70 % and 80-20 % as the desired range of state of health (SOH), the optimum capacity of 34kWh ESS can deliver the highest net saving of 21,141 MYR (4727 USD) to the university over 17.3 years. On the other hand, the optimum capacity of 52 kWh ESS can achieve the maximum net saving of 78,924 MYR (17,647 USD) to a factory over 5.2 years under the DOD of 100 % with 100-80 % as the desired range of SOH.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available