4.8 Article

Numerical and experimental investigation of thermosyphon-driven liquid desiccant loop performance for sustainable indoor humidity removal*

Journal

APPLIED ENERGY
Volume 343, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2023.121215

Keywords

Humidity pump; Liquid desiccant dehumidification; Thermosyphon loop; Breathable insulation; Potassium formate

Ask authors/readers for more resources

Indoor humidity management is a challenging task, particularly in hot and humid climates, and requires a significant amount of energy. This study proposes a new method using desiccants to remove water vapor from indoor air. By utilizing thermosyphon and membrane technology, this system can sustainably regulate humidity between different areas. Mathematical models were developed and validated, and it was found that the system can effectively move moisture from high to low humidity areas under various climatic conditions. The required heat input is dependent on the membrane area and varies between 150 W to 570 W.
Indoor humidity management is one of the most challenging aspects of the control of indoor environment and is energy intensive, especially in hot and humid climates. A promising approach is the removal of the water vapor from the room using hygroscopic materials, otherwise known as desiccants. Desiccant cycles are thermally driven but require a heat sink and electricity-driven mechanical parts for desiccant circulation. Accordingly, this work proposes a thermosyphon-driven membrane-based liquid desiccant loop for sustainable humidity pumping between two areas at different humidity conditions. Mathematical models were developed for the different system subcomponents, which were validated with published data and in-house experiments. The models were used in a parametric study to determine the influence of the design and operation parameters on the system performance under different air conditions surrounding its various sections.It was found that the system was able to pump the air moisture from high to low and low to high humidity areas. Four cases were considered with outdoor conditions raging from moderate and hot and humid to semi-arid climates. The latent load removal density per unit area of the exposed membrane varied between 4 W/m2 to 35 W/m2 over the entire range of considered cases at required heat inputs varying between 150 W and 570 W

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available