4.8 Article

Tailoring Efficient Fluorogenic Tactic for Ultrasensitive Detection of Dopamine in Urine and Rat Brain through Real-Time and In Situ Formation of High-Performance Fluorophore

Journal

ANALYTICAL CHEMISTRY
Volume 95, Issue 43, Pages 15965-15974

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.3c03035

Keywords

-

Ask authors/readers for more resources

This article describes an efficient fluorogenic strategy for ultrasensitive detection of dopamine (DA). The method offers rapid response, wide linear range, good selectivity, and sensitivity, and has been successfully applied for the measurement of DA content in practical urine samples and evaluation of DA levels in a rat model of depression.
Owing to the predominance of dopamine (DA) in controlling mental health, planning an innovative method for DA detection with simplicity and high efficacy is conducive to the assessment of neurological disorders. Herein, an efficient fluorogenic tactic has been elaborated for ultrasensitive detection of DA with remarkably enhanced turn-on response. Utilizing a twisted intramolecular charge-transfer (TICT)-suppressing strategy, a highly emissive azocine derivative 11-hydroxy-2,3,6,7,11,12,13,14-octahydro-1H,5H,10H-11,14a-methanoazocino[5 ',4 ':4,5]furo[2,3-f]pyrido[3,2,1-ij]quinolin-10-one (J-Aza) is generated via a one-step reaction between DA and 8-hydroxyjulolidine. It is marvelous that J-Aza not only possesses ideal fluorescence quantum yield (Phi(F)) as high as 0.956 but also exhibits bathochromic shifted fluorescence (green emissive) and stronger anti-photobleaching capacity superior to traditional azocine-derived 1,2,3,4-tetrahydro-5H-4,11a-methanobenzofuro[2,3-d]azocin-5-one (Aza) with moderate Phi(F), blue fluorescence, and poor photostability. By confining the TICT process, the detection limit to DA can be reduced to 80 pM, which is competitive in contrast to previously reported fluorescence methods. Encouraged by the instant response (within 90 s), wide linear range (0.1-500 nM), great selectivity, and excellent sensitivity, this fluorogenic method has been used for the real-time measurement of DA contents in practical urine samples with satisfactory results. Furthermore, the cerebral DA level in the reserpine-induced depression rat model has also been evaluated by our designed method, demonstrating its potent analytical applicability in the biosensing field.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available