3.8 Article

Reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay as a rapid molecular diagnostic tool for COVID-19 in healthcare workers

Journal

JOURNAL OF CLINICAL VIROLOGY PLUS
Volume 3, Issue 2, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.jcvp.2023.100134

Keywords

COVID-19; RT-LAMP; SARS-CoV-2; Healthcare workers

Ask authors/readers for more resources

This study evaluated the performance of the reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for detecting SARS-CoV-2 in healthcare workers and compared it with the real-time reverse-transcription quantitative PCR (RT-qPCR) method. The results showed that the RT-LAMP method was effective in diagnosing SARS-CoV-2 infection in healthcare workers. A total of 100 clinical specimens from symptomatic and asymptomatic healthcare workers in Pelotas, Brazil were tested, and the E gene and N gene primers detected SARS-CoV-2 in 96.7% of the tested healthcare workers.
In December 2019, the Chinese Center for Disease Control (CDC of China) reported an outbreak of pneumonia in the city of Wuhan (Hubei province, China) that haunted the world, resulting in a global pandemic. This outbreak was caused by a betacoronavirus named severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Several of these cases have been observed in healthcare professionals working in hospitals and providing care on the pandemic's frontline. In the present study, nasopharyngeal swab samples of healthcare workers were used to assess the performance of the reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay and subsequently compared with the real -time reverse-transcription quantitative PCR (RT-qPCR) method. Thus, in this study, we validated a method for detecting SARS-CoV-2 based on RT-LAMP that can be used to diagnose these workers. The methodology used was based on analyzing the sensitivity, specificity, evaluation of the detection limit, and cross-reaction with other respiratory viruses. The agreement was estimated using a dispersion diagram designed using the Bland-Altman method. A total of 100 clinical specimens of nasopharyngeal swabs were collected from symptomatic and asymptomatic healthcare workers in Pelotas, Brazil, during the SARS-CoV-2 outbreak. RT-LAMP assay, it was possible to detect SARS-CoV-2 in 96.7% of the healthcare professionals tested using the E gene and N gene primers approximately and 100% for the gene of human beta-actin. The observed agreement was considered excellent for the primer set of the E and N genes ( k = 0.957 and k = 0.896), respectively. The sensitivity of the RT-LAMP assay was positive for the primer set of the E gene, detected to approximately 2 copies per reaction. For the primer set of the N gene, the assay was possible to verify an LoD of approximately 253 copies per reaction. After executing the RT-LAMP assay, no positive reactions were observed for any of the virus respiratory tested. Therefore, we conclude that RT-LAMP is effective for rapid molecular diagnosis during the COVID-19 outbreak period in healthcare professionals.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available