4.1 Article

Simulation Study on Suppressing Shielded Fires by Water Mist Systems

Related references

Note: Only part of the references are listed.
Article Ecology

Full-Scale Experiments of Water-Mist Systems for Control and Suppression of Sauna Fires

Paolo E. E. Santangelo et al.

Summary: The design and evaluation of fire protection systems in saunas are crucial. Water mist has been found to be a promising option for controlling and suppressing fires, providing guidelines for designers. Experiments were conducted using timber benches as target materials and varying design parameters.

FIRE-SWITZERLAND (2022)

Article Ecology

On the Large Eddy Simulation Modelling of Water Suppression Systems Droplet Impact and Coverage Area

Ivan Miguel De Cachinho Cordeiro et al.

Summary: This study establishes a database to investigate the suppression effects of water-based suppression systems under different configurations and fire locations. The results show that the water mist system can effectively control fires above 200 degrees Celsius with a relatively short suppression time.

FIRE-SWITZERLAND (2022)

Article Engineering, Environmental

Full-scale experimental study on water mist fire suppression in a railway tunnel rescue station: Temperature distribution characteristics

Chuangang Fan et al.

Summary: The study conducted 20 sets of full-scale water mist fire suppression experiments to examine the impacts of water mist system on smoke temperature characteristics. Results showed that optimal temperature control could be achieved when t = 3 min, P = 12 MPa, and K = 0.5. Longitudinal ventilation was found to improve visibility at platform and reduce smoke temperature, especially when coupled with a working pressure of 12 MPa.

PROCESS SAFETY AND ENVIRONMENTAL PROTECTION (2021)

Article Engineering, Environmental

Experimental investigation on spray characteristics of twin-fluid nozzle for water mist and its heptane pool fire extinguishing performance

Chan Seok Jeong et al.

Summary: The study indicates that the twin-fluid nozzle outperforms the single-fluid nozzle in fire extinguishing performance, being able to extinguish fires faster and more effectively, while using less water. Additionally, the airflow of the twin-fluid nozzle is identified as a critical factor affecting its fire suppression capabilities.

PROCESS SAFETY AND ENVIRONMENTAL PROTECTION (2021)

Article Engineering, Civil

The combined effect of a water mist system and longitudinal ventilation on the fire and smoke dynamics in a tunnel

Yuanjun Liu et al.

Summary: The study found that the combined effect of a water mist system (WMS) and longitudinal ventilation (LV) has a complex impact on fire HRR and smoke temperature. The velocity and water volume flow rate of WMS and LV have significant effects on reducing fire, and the combined effect of WMS and LV can lead to non-monotonic behavior. Activating WMS can significantly reduce the required ventilation velocities for a specific back-layering distance.

FIRE SAFETY JOURNAL (2021)

Article Engineering, Environmental

Preliminary study on extinguishing shielded fire with water mist

Yangpeng Liu et al.

PROCESS SAFETY AND ENVIRONMENTAL PROTECTION (2020)

Article Green & Sustainable Science & Technology

Performance evaluation of water mist fire suppression: A clean and sustainable fire-fighting technique in mechanically-ventilated place

Yang Zhou et al.

JOURNAL OF CLEANER PRODUCTION (2019)

Article Construction & Building Technology

Experimental study of the effectiveness of a water mist segment system in blocking fire-induced smoke and heat in mid-scale tunnel tests

Qi Li et al.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2019)

Article Engineering, Environmental

Experimental study on fire smoke control using water mist curtain in channel

Zhigang Wang et al.

JOURNAL OF HAZARDOUS MATERIALS (2018)

Article Construction & Building Technology

Numerical studies on the smoke control by water mist screens with transverse ventilation in tunnel fires

Qiang Liang et al.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2017)

Article Engineering, Chemical

Optimization of water mist droplet size by using CFD modeling for fire suppressions

Zhen Wang et al.

JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES (2016)

Article Engineering, Civil

Experimental and numerical study of pool fire suppression using water mist

A. Jenft et al.

FIRE SAFETY JOURNAL (2014)

Article Engineering, Multidisciplinary

Modeling and Simulation of High Pressure Water Mist Systems

Topi Sikanen et al.

FIRE TECHNOLOGY (2014)

Article Thermodynamics

An experimental study of the effects of water mist characteristics on pool fire suppression

Meenakshi Gupta et al.

EXPERIMENTAL THERMAL AND FLUID SCIENCE (2013)

Proceedings Paper Engineering, Civil

Experimental data on water mist suppression

Jun Qin et al.

9TH ASIA-OCEANIA SYMPOSIUM ON FIRE SCIENCE AND TECHNOLOGY (2013)

Article Nuclear Science & Technology

Numerically investigating fire suppression mechanisms for the water mist with various droplet sizes through FDS code

Yuh-Ming Ferng et al.

NUCLEAR ENGINEERING AND DESIGN (2011)

Article Construction & Building Technology

Experimental and numerical study on water mist suppression system on room fire

Peizhong Yang et al.

BUILDING AND ENVIRONMENT (2010)

Article Transportation Science & Technology

Spray Characteristics Study of DMF Using Phase Doppler Particle Analyzer

Guohong Tian et al.

SAE INTERNATIONAL JOURNAL OF PASSENGER CARS-MECHANICAL SYSTEMS (2010)

Article Engineering, Civil

Comparison of PIV and PDA droplet velocity measurement techniques on two high-pressure water mist nozzles

Bjarne Paulsen Husted et al.

FIRE SAFETY JOURNAL (2009)

Article Engineering, Multidisciplinary

Extinction Limit of Diesel Pool Fires Suppressed by Water Mist

Cong Beihua et al.

JOURNAL OF FIRE SCIENCES (2009)

Article Construction & Building Technology

An experimental and numerical study on fire suppression using a water mist in an enclosure

SC Kim et al.

BUILDING AND ENVIRONMENT (2003)