3.8 Article

Enhanced Readability of Electrical Network Complex Emergency Modes Provided by Data Compression Methods

Journal

INFORMATION
Volume 14, Issue 4, Pages -

Publisher

MDPI
DOI: 10.3390/info14040230

Keywords

multi-parameter relay protection; long-range redundancy; sensitivity; data compression; simulation; principal component analysis method; Fisher's linear discriminant analysis

Ask authors/readers for more resources

This article explores the issues of enhanced sensitivity of multi-parameter relay protection using long-range redundancy protection as an example. Transition to generalized features is proposed in order to simplify multi-parameter protection and reduce the computational load on the RPA device.
Current microprocessor-based relay protection and automation (RPA) devices supported by IEC 61850 provide access to a large amount of information on the protected or controlled electric power facility in real time. The issue of using such information (Big Data) in order to improve the parameters of technical modification of intelligent electronic devices at digital substations remains unaddressed. Prerequisites arise for designing modern power systems with relay protection devices of a new generation based on new information algorithms. In particular, it is expedient to develop multi-parameter protections using more than one information parameter: modules of current, voltage, derivatives thereof, phase angles, active and reactive resistances, etc. An information approach based on multiple modeling and statistical processing of modeling results is also promising. This article explores the issues of enhanced sensitivity of multi-parameter relay protection using long-range redundancy protection as an example. Transition to generalized features is proposed in order to simplify multi-parameter protection and reduction in the computational load on the RPA device. Out of a large number of analyzed indicators (currents, voltages, their derivatives, resistances, increments of currents, angles between current and voltage, etc.), we specify the most informative by using the method of data compression. The transition to generalized features simplifies the parameterization of settings, and the process of making a decision by the relay protection device is reduced to obtaining a generalized feature and comparing it with a dimensionless setting in relative terms. For the formation of generalized information features, two mathematical methods are studied: the method of principal components and Fisher's linear discriminant.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available