3.8 Article

Standardization of Latency and Amplitude Values of Short, Middle and Long Latency Auditory Evoked Potentials in Adults

Journal

INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY
Volume 27, Issue 2, Pages E278-E285

Publisher

GEORG THIEME VERLAG KG
DOI: 10.1055/s-0043-1768203

Keywords

electrophysiology; hearing; adults; audiology

Ask authors/readers for more resources

This study aimed to standardize latency and amplitude values for short-, middle-, and long-latency auditory evoked potentials in adults with normal hearing thresholds. The results showed that the absolute latency and interpeak values for middle- and long-latency auditory evoked potentials were lower than internationally suggested. However, the means for brainstem auditory evoked potential were within the range considered as normal. This study provided measurements of normal latencies and amplitudes for short-, middle-, and long-latency auditory evoked potentials in adults.
Introduction Auditory processing refers to the efficiency and effectiveness with which the central auditory nervous system uses auditory information. Middle- and long-latency auditory evoked potentials are objective electrophysiological tests that can complement the diagnosis of alterations involving central auditory processing. Objective To standardize latency and amplitude values for short-, middle-, and long-latency auditory evoked potentials in adults with normal hearing thresholds. Methods This is a cross-sectional study. Thirty-three adults with normal hearing thresholds, without hearing complaints, and with normal central auditory processing were evaluated. All underwent basic audiological evaluation, central auditory processing assessment, and short-, middle-, and long-latency auditory evoked potentials. Results Absolute latency and interpeak values for middle- and long-latency auditory evoked potentials were lower than internationally suggested. However, for the brainstem auditory evoked potential, the means were within the range considered as normal, as suggested in the equipment. Conclusion The present study provided measurements of normal latencies and amplitudes for short-, middle-, and long-latency auditory evoked potentials in adults.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available