Balancing performance of active magnetic regenerators: a comprehensive experimental study of aspect ratio, particle size, and operating conditions

Journal

JOURNAL OF PHYSICS-ENERGY
Volume 5, Issue 2, Pages -

Publisher

IOP Publishing Ltd
DOI: 10.1088/2515-7655/acc1a0

Keywords

solid-state refrigeration; magnetocaloric effect; gadolinium; heat transfer; geometry

Ask authors/readers for more resources

The influence of regenerator shape, magnetocaloric material size, operating frequency, and utilization on the performance of gadolinium packed-particle bed AMRs is experimentally demonstrated. System performance is evaluated using observed temperature spans and cooling powers across a wide range of operating conditions. The study shows improvements in specific cooling power and maximum temperature span for gadolinium with respect to optimized utilization and operating frequency.
Effective and, at the same time, efficient active magnetic regenerator (AMR) performance requires balanced geometry and operating conditions. Here the influence of regenerator shape, magnetocaloric material size, operating frequency, and utilization on the performance of gadolinium packed-particle bed AMRs is demonstrated experimentally. Various metrics are applied to assess effectiveness and efficiency. Observed temperature spans and cooling powers across a wide range of operating conditions are used to evaluate system performance and estimate exergetic cooling power and exergetic power quotient. A new metric combining exergetic cooling power and pump power provides an estimate of the maximum achievable second law efficiency. Five regenerator geometries with equal volumes and the aspect ratio from 1.0 to 3.8, and four different ranges of Gd spherical particles between 182 and 354 mu m, are investigated. Improvements in system performance are demonstrated by a boost in specific cooling power of gadolinium from 0.85 to 1.16 W g(-1) and maximum temperature span from 8.9 to 15.1 K. The optimum exergetic cooling power is observed for 1.37 utilization and 3 Hz operating frequency, exergetic power quotient exhibits a maximum at the same utilization but at 2 Hz frequency, while the highest efficiency is recorded at 1 Hz and utilization of 0.5, demonstrating that multiple performance metrics must be balanced to achieve regenerator design meeting all performance targets.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available