4.4 Article

Ultra-High Resolution Optical Aberrometry in Patients with Keratoconus: A Cross-Sectional Study

Related references

Note: Only part of the references are listed.
Review Ophthalmology

被撤回的出版物: The association between keratoconus and allergic eye diseases: A systematic review and meta-analysis (Retracted article. See vol. 51, pg. 183, 2023)

Ishith Seth et al.

Summary: This study investigated the association between keratoconus and allergic eye diseases, eye rubbing, and atopy. The results showed no significant association between keratoconus and allergic eye diseases, eye rubbing, or atopy. Further prospective studies are needed to validate these findings.

CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY (2022)

Article Ophthalmology

Best Indicators for Detecting Keratoconus Progression in Children: A Report From the Shahroud Schoolchildren Eye Cohort Study

Hassan Hashemi et al.

Summary: This study aimed to investigate the indicators of keratoconus (KC) progression in children and compare them with age-related changes. The results showed that index of height decentration, Zonal Kmax-3 mm, refractive astigmatism, single point Kmax, and index of vertical asymmetry were the best indices for detecting KC progression in children younger than 12 years.

CORNEA (2022)

Article Ophthalmology

Assessing the visual image quality provided by refractive corrections during keratoconus progression

Jos J. Rozema et al.

Summary: The study expands the SyntEyes KTC model to assess the VIQ of spherical-cylindrical spectacle and rigid contact lens corrections as keratoconus progresses. Results show that as the disease progresses, the visual Strehl ratio pattern in correction space for spectacles changes from an hourglass to a shell pattern, impacting the subjective refraction and VIQ differently.

OPHTHALMIC AND PHYSIOLOGICAL OPTICS (2022)

Article Multidisciplinary Sciences

Predicting factors for the efficacy of cross-linking for keratoconus

Denise Wajnsztajn et al.

Summary: This study evaluated predictors for success in corneal crosslinking (CXL) for keratoconus. The results showed that CXL was more successful in eyes with high Kmax(pre), high SEpre, and high LogMAR(pre). The non-accelerated epithelium-off protocol resulted in greater flattening of corneal curvature, but had similar effects on visual acuity compared to other protocols.

PLOS ONE (2022)

Article Ophthalmology

Keratoconus: Diagnosis and Staging

Michael W. Belin et al.

Summary: The development of tomographic imaging has allowed for the recognition of early or subclinical ectatic disease, making it useful for screening refractive surgery patients. The screening tools utilized by tomographic imaging devices aid in diagnosing corneal disease, and the Belin ABCD staging and classification system can be used for earlier intervention and prevention of visual loss in keratoconus.

CORNEA (2022)

Article Ophthalmology

An exploratory analysis of forme fruste keratoconus sensitivity diagnostic parameters

Hui Zhang et al.

Summary: Secondary statistical analysis of Pentacam or Corvis ST parameters extracted sensitive diagnostic parameters for clinical keratoconus (CKC) and forme fruste keratoconus (FFKC). Important parameters related to the thinnest point of cornea were identified, with SPA1 being the only Corvis ST output parameter sensitive to FFKC. A meta-analysis on SPA1 showed high sensitivity and potential for early detection of corneal biomechanical changes in FFKC.

INTERNATIONAL OPHTHALMOLOGY (2022)

Article Multidisciplinary Sciences

High-frequency ultrasound detects biomechanical weakening in keratoconus with lower stiffness at higher grade

Sunny Kwok et al.

Summary: This study developed a high-frequency ultrasound elastography method to characterize the biomechanics of the cornea and compared the differences between keratoconus patients and normal controls. The results showed that keratoconus corneas had increased axial displacement and decreased stiffness compared to normal corneas, and these parameters were strongly correlated with disease severity. The study suggests a biomechanical weakening in keratoconus and demonstrates the ability of high-frequency ultrasound elastography to accurately evaluate the cornea's biomechanical condition in vivo, which can aid in the early and definitive diagnosis and staging of keratoconus.

PLOS ONE (2022)

Article Ophthalmology

Keratoconus detection of changes using deep learning of colour-coded maps

Xu Chen et al.

Summary: The study evaluated the accuracy of convolutional neural networks technique in detecting keratoconus using colour-coded corneal maps obtained by a Scheimpflug camera. Results showed that the CNN model has excellent detection performance and can accurately differentiate between different severities of the disease, with potential for screening and management of keratoconus.

BMJ OPEN OPHTHALMOLOGY (2021)

Review Ophthalmology

Eye rubbing in the aetiology of keratoconus: a systematic review and meta-analysis

Srujana Sahebjada et al.

Summary: Eye rubbing is consistently associated with keratoconus, but current evidence is limited to a small number of case-control studies that are heterogeneous and of sub-optimal methodological quality. Further research is needed to explore the intricate relationship between eye rubbing and the induction, ongoing progression, and severity of keratoconus.

GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY (2021)

Article Ophthalmology

Comprehensive evaluation of corneas from normal, forme fruste keratoconus and clinical keratoconus patients using morphological and biomechanical properties

Hui Zhang et al.

Summary: This study evaluated the parameters reflecting the morphological and biomechanical properties of the cornea to distinguish CKC and FFKC from normal eyes. The combination of parameters from Pentacam and Corvis ST showed effectiveness in distinguishing CKC and FFKC, with different levels of predictive accuracy.

INTERNATIONAL OPHTHALMOLOGY (2021)

Article Ophthalmology

Epithelial Flap Corneal Cross-linking

Davide Borroni et al.

Summary: This study compared the outcomes of standard epithelium-off corneal cross-linking and corneal cross-linking with an epithelial flap for patients with progressive keratoconus. The results showed that the epithelial flap technique was associated with less postoperative pain and anterior stromal haze, with no loss of efficacy at 12 months postoperatively.

JOURNAL OF REFRACTIVE SURGERY (2021)

Article Multidisciplinary Sciences

The optics of the human eye at 8.6 μm resolution

Sergio Bonaque-Gonzalez et al.

Summary: This study characterized the ocular optics of human eye with a high resolution method, revealing previously unknown optical patterns that could have a significant impact on our understanding of human vision mechanisms.

SCIENTIFIC REPORTS (2021)

Article Ophthalmology

Repeatability and reliability of measurements obtained by the combined Scheimpflug and Placido-disk tomography in different stages of keratoconus

Ugur Tunc et al.

Summary: This study evaluated the repeatability and reliability of corneal parameters in keratoconus patients using a combined Scheimpflug-Placido disc analysis system. The study found that corneal curvature parameters were less repeatable as keratoconus severity increased, while corneal aberrations showed repeatability in all keratoconus subgroups.
Article Ophthalmology

Keratometric indices for detecting the type of keratoconus: a combined discriminant analysis

Ali Yousefi et al.

CLINICAL AND EXPERIMENTAL OPTOMETRY (2020)

Article Ophthalmology

Classification of Keratoconus Based on Anterior Corneal High-order Aberrations: A Cross-validation Study

Sara Ortiz-Toquero et al.

OPTOMETRY AND VISION SCIENCE (2020)

Article Ophthalmology

Evaluation of keratoconus progression

Mehdi Shajari et al.

BRITISH JOURNAL OF OPHTHALMOLOGY (2019)

Article Ophthalmology

Clinical evaluation of the repeatability of ocular aberrometry obtained with a new pyramid wavefront sensor

Ana B. Plaza-Puche et al.

EUROPEAN JOURNAL OF OPHTHALMOLOGY (2019)

Article Ophthalmology

Effect of intraocular lens decentration on image quality tested in a custom model eye

Pablo Perez-Merino et al.

JOURNAL OF CATARACT AND REFRACTIVE SURGERY (2018)

Article Ophthalmology

Keratoconus: The ABCD Grading System

M. W. Belin et al.

KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE (2016)

Article Ophthalmology

Anterior Corneal, Posterior Corneal, and Lenticular Contributions to Ocular Aberrations

David A. Atchison et al.

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE (2016)

Article Ophthalmology

Global Consensus on Keratoconus and Ectatic Diseases

Jose A. P. Gomes et al.

CORNEA (2015)

Review Ophthalmology

Biomechanical properties of the keratoconic cornea: a review

Hans R. Vellara et al.

CLINICAL AND EXPERIMENTAL OPTOMETRY (2015)

Article Ophthalmology

The pathogenesis of keratoconus

A. E. Davidson et al.

Review Ophthalmology

Clinical Applications of Wavefront Refraction

Adrian S. Bruce et al.

OPTOMETRY AND VISION SCIENCE (2014)

Article Ophthalmology

Precision of a Commercial Hartmann-Shack Aberrometer: Limits of Total Wavefront Laser Vision Correction

Alberto Lopez-Miguel et al.

AMERICAN JOURNAL OF OPHTHALMOLOGY (2012)

Article Ophthalmology

Aberrations and Topography in Normal, Keratoconus-Suspect, and Keratoconic Eyes

Ariela Gordon-Shaag et al.

OPTOMETRY AND VISION SCIENCE (2012)

Article Ophthalmology

Repeatability of ocular aberration measurements in patients with keratoconus

Amit Jinabhai et al.

OPHTHALMIC AND PHYSIOLOGICAL OPTICS (2011)

Article Ophthalmology

Pentacam posterior and anterior corneal aberrations in normal and keratoconic eyes

David P. Pinero et al.

CLINICAL AND EXPERIMENTAL OPTOMETRY (2009)

Article Ophthalmology

The significance of Vogt's striae in keratoconus as evaluated by in vivo confocal microscopy

Mehmet C. Mocan et al.

CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY (2008)

Article Optics

Mechanism of compensation of aberrations in the human eye

Juan Tabernero et al.

JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION (2007)

Article Optics

Three-dimensional relationship between high-order root-mean-square wavefront error, pupil diameter, and aging

Raymond A. Applegate et al.

JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION (2007)

Article Optics

Analysis of the performance of the Hartmann-Shack sensor in the human eye

PM Prieto et al.

JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION (2000)